Evidence map›Paper›PMID 39081855›Full record

ArticleJournal of ophthalmology2024

Efficacy and Safety of PreserFlo MicroShunt Implantation and Its Effects on Intraocular Inflammation through Laser Flare Photometry.

Carlo Cagini, Niccolò Boni, Tommaso Bonifazi, Daniela Fruttini, Francesco Della Lena

Abstract read
In one paragraph

Article in Journal of ophthalmology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Carlo CaginiUniversity of Perugia School of Medicine and Surgery Department of Medicine and Surgery Section of Ophthalmology Ospedale S. Maria della Misericordia, Perugia 06156, Italy.ORCID https://orcid.org/0000-0002-3812-9219
Niccolò BoniUniversity of Perugia School of Medicine and Surgery Department of Medicine and Surgery Section of Ophthalmology Ospedale S. Maria della Misericordia, Perugia 06156, Italy.
Tommaso BonifaziUniversity of Perugia School of Medicine and Surgery Department of Medicine and Surgery Section of Ophthalmology Ospedale S. Maria della Misericordia, Perugia 06156, Italy.
Daniela FruttiniUniversity of Perugia School of Medicine and Surgery Department of Medicine and Surgery Section of Ophthalmology Ospedale S. Maria della Misericordia, Perugia 06156, Italy.ORCID https://orcid.org/0000-0002-4360-4627
Francesco Della LenaUniversity of Perugia School of Medicine and Surgery Department of Medicine and Surgery Section of Ophthalmology Ospedale S. Maria della Misericordia, Perugia 06156, Italy.ORCID https://orcid.org/0009-0001-6535-9124

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: The primary objective of this study is to evaluate the efficacy and safety profile of PreserFlo MicroShunt implantation in the medium- to long-term follow-up of patients with open-angle glaucoma. The secondary objective is to analyze laser flare meter (LFM) values before and after PreserFlo MicroShunt implantation. Methods: This prospective, observational, longitudinal single-center study included a total of 62 eyes from 54 patients. A subgroup of 27 eyes (26 patients) reached the 12-month follow-up. Success was defined based on three criteria: criterion A: IOP ≤21 mmHg and ≥20% reduction; criterion B: IOP ≤15 mmHg and ≥25% reduction; and criterion C: IOP ≤12 mmHg and ≥30% reduction. Success was further categorized as complete if achieved without IOP-lowering medications and qualified if achieved with medication administration. Other aspects evaluated included the number of IOP-lowering medications (baseline and postoperative), development of postoperative complications, 5-FU injections or implant revision, and LFM values. Results: The 12-month follow-up group (27 patients) was composed by 50% males and had a mean age of 75.54 ± 9.98 years. Success rates at 12 months were as follows: 78% for criterion A, 56% for criterion B, and 26% for criterion C. Complete success, as defined by criterion A, was achieved by 67% of the patients, 29% achieved qualified success, and one eye (4%) experienced failure. IOP decreased from 25.26 ± 1.67 mmHg at baseline to 14.81 ± 0.74 mmHg at 12 months. The number of medications decreased from 3.67 ± 1.30 at baseline to 0.48 ± 0.75 at 12 months. Reported complications were choroidal detachment (11%), hyphema (5%), and athalamia (flat anterior chamber) (2%) 13 eyes (48%) received 5-FU injections, while 7 eyes (26%) underwent implant revision. No significant increase in LFM values was observed. Eyes with a regular postoperative course and IOP ≤15 mmHg showed significantly lower LFM values than patients with unfavorable outcomes (IOP >15 mmHg, development of complications, 5-FU injection, or implant revision). Conclusions: PreserFlo MicroShunt showed a significant reduction in IOP and a decrease in the number of IOP-lowering medications. Complications occurred at a modest frequency. The implant provides a minimally invasive approach with no significant increases in LFM values postoperatively. Higher LFM values correlate with unfavorable postoperative outcomes.

Identifiers

PMID39081855
PMCPMC11288689

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.