Evidence map›Paper›PMID 39080768›Full record

ArticleJournal of orthopaedic surgery and research2024

Impact of screw tip design on screw anchorage: mechanical testing and numerical simulation.

Shiming Xie, Liqiang Cui, Jinhui Liu, Peidong Qing, Jingchi Li

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Shiming Xie *Department of Spine surgery, Mianyang Orthopedic Hospital, Mianyang, Sichuan Province, 621052, P.R. China.
Liqiang Cui *Department of Spine surgery, Mianyang Orthopedic Hospital, Mianyang, Sichuan Province, 621052, P.R. China.
Jinhui LiuSichuan Provincial Laboratory of Orthopaedic Engineering, Department of Bone and Joint Surgery, Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan Province, PR China.
Peidong QingDepartment of Spine surgery, Mianyang Orthopedic Hospital, Mianyang, Sichuan Province, 621052, P.R. China. qpdorthopaedic@163.com.
Jingchi LiDepartment of Orthopedics, Luzhou Key Laboratory of Orthopedic Disorders, The Affiliated Traditional Chinese Medicine Hospital, Southwest Medical University, Luzhou, Sichuan Province, 646000, P.R. China. lijingchi9405@163.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundScrew loosening is a commonly reported issue following spinal screw fixation and can lead to various complications. The initial cause of screw loosening is biomechanical deterioration. Previous studies have demonstrated that modifications in screw design can impact the local biomechanical environment, specifically the stress distribution on bone-screw interfaces. There are several different designs of screw tips available for clinically used pedicle screws; however, it remains unclear whether these variations affect the local stress distribution and subsequent screw anchorage ability.

methodsThis study conducted comprehensive biomechanical research using polyurethane foam mechanical tests and corresponding numerical simulations to investigate this topic. Models of pedicle screw-fixed osteoporotic polyurethane foam were created with two different clinically used screw tip designs (flat and steep) featuring varying tip lengths, taper angles, and diameters, as well as identical flank overlap areas and thread designs. The anchorage ability of the different models was assessed through toggle and pull-out test. Additionally, numerical mechanical models were utilized to compute the stress distributions at the screw and bone-screw interfaces in the different models.

resultsMechanical tests revealed superior anchorage ability in models utilizing flat-tipped screws. Furthermore, numerical modeling indicated improved anchorage ability and reduced stress concentration tendency in these models.

conclusionChanges in screw tip design can significantly impact the biomechanical anchoring capability of screws. Specifically, flatter tip pedicle screws may mitigate the risk of screw loosening by alleviating stress concentration on bone-screw interfaces.

Indexed as

Materials TestingPedicle ScrewsBiomechanical PhenomenaBone ScrewsComputer SimulationEquipment DesignHumansPolyurethanesStress, MechanicalPolyurethanesBone-screw interfacesPedicle screwScrew anchorage abilityScrew looseningScrew tip design

Identifiers

PMID39080768
PMCPMC11287948

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.