Evidence map›Paper›PMID 39080358›Full record

ArticleScientific reports2024

Dual layer energy management model for optimal operation of a community based microgrid considering electric vehicle penetration.

Pavitra Sharma, Debjanee Bhattacharjee, Hitesh Datt Mathur, Puneet Mishra

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Pavitra SharmaDepartment of Electrical and Electronics Engineering, Birla Institute of Technology and Science, Pilani, Pilani, Rajasthan, India. sharmapavitra334@gmail.com.
Debjanee BhattacharjeeDepartment of Electrical and Electronics Engineering, Birla Institute of Technology and Science, Pilani, Pilani, Rajasthan, India.
Hitesh Datt MathurDepartment of Electrical and Electronics Engineering, Birla Institute of Technology and Science, Pilani, Pilani, Rajasthan, India.
Puneet MishraDepartment of Electrical and Electronics Engineering, Birla Institute of Technology and Science, Pilani, Pilani, Rajasthan, India.

Funding

Department of Science and Technology, Govt. of India, New Delhi DST/ICPS/CLUSTER/IoT/2018/General
6 · The paper itself

Abstract

This work develops a dual-layer energy management (DLEM) model for a microgrid (MG) consisting of a community, distributed energy resources (DERs), and a grid. It ensures the participation of all these energy entities of MG in the market and their interaction with each other. The first layer performs the scheduling operation of the community with the goal of minimizing its net-billing cost and sends the obtained schedule to the DER operator and grid. Further, the second layer formulates a power scheduling algorithm (PSA) to minimize the net-operating cost of DERs and takes into account the load demand requested by the community operator (COR). This PSA aims to achieve optimal operation of MG by considering solar PV power, requested demand, per unit grid energy prices, and state of charge of the battery energy storage system of the DER layer. Moreover, to study the impact of electric vehicles (EVs) load programs on DLEM, the advanced probabilistic EV load profile model is developed considering practical and uncertain events. The EV load is modelled for grid to vehicle mode, and a new mode of EV operation is introduced, i.e., vehicle to grid with EV demand response strategy (V2G_DRS) mode. The solar PV and load demand data are obtained from the MG setup installed and buildings present at the university campus. However, a scenario reduction technique is used to deal with the uncertainties of the obtained data. In order to evaluate the efficacy of the developed DLEM, its results are compared to previously reported energy management models. The results reveal that DLEM is superior to the existing models as it decreases the net-billing cost of COR by 13% and increases the profit of the DER operator by 17%. Further, it is found that for the highest EV penetration, i.e., 30 EVs, the V2G_DRS mode of EV operation reduces the total energy imported by COR by 11.39% and the net-billing cost of COR by 7.88%. Therefore, it can be concluded that the proposed model with the introduced V2G_DRS mode of EV makes the operation of all the entities of MG more economical and sustainable.

Indexed as

Battery energy storage systemBuildingsDemand response strategyElectric vehicleEnergy managementMicrogridsSolar PV systemVehicle to grid

Identifiers

PMID39080358
PMCPMC11289451

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.