Evidence map›Paper›PMID 39080195›Full record

ArticleAnalytical sciences : the international journal of the Japan Society for Analytical Chemistry2024

Development of a HPLC system using a phase-separation multiphase flow as an eluent: an influence of column pressure on phase separation and chromatogram at room temperature.

Keisuke Takagi, Takeshi Iharada, Kazuhiko Tsukagoshi

Abstract read
PubMed Publisher
In one paragraph

Article in Analytical sciences : the international journal of the Japan Society for Analytical Chemistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Recent development of surface treatment of polytetrafluoroethylene.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2025
    Article
  2. Direct visualization of phase-separation multiphase flow in a silica bead-packed microchannel using fluorescence microscopy.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Keisuke TakagiApplied Chemistry, Graduate School of Science and Engineering, Doshisha University, Kyotanabe, 610-0321, Japan.
Takeshi IharadaApplied Chemistry, Graduate School of Science and Engineering, Doshisha University, Kyotanabe, 610-0321, Japan.
Kazuhiko TsukagoshiApplied Chemistry, Graduate School of Science and Engineering, Doshisha University, Kyotanabe, 610-0321, Japan. ktsukago@mail.doshisha.ac.jp.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We have developed a HPLC system where phase-separation multiphase flow works in the separation column as an eluent. We call the novel separation mechanism a phase-separation mode. The ternary mixed solution of water/acetonitrile/ethyl acetate, which is one of the two-phase-separation mixed solutions, caused the phase-separation multiphase flow via phase change from homogeneous to heterogeneous with the temperature effect (from 20 to 0 °C). In this study, we tried to perform phase-separation multiphase flow with the pressure effect instead of the temperature one. The fused-silica capillary tube (50 cm length and 50 µm inner diameter) was allied to the downstream of the column to apply the pressure of 5.5 MPa to the system. Model analytes of 2,6-naphthalenedisulfonic acid (2,6-NDS) and 1-naphthol (1-NA) were examined. For example, solutions (the volume% of water/acetonitrile/ethyl acetate; 20:55:25, organic-rich) and (60:30:10, water-rich) were used as eluent. The model analytes were not separated with both solutions at the pressure of 1.5 MPa and 20 °C. But with the organic-rich solution, 1-NA and 2,6-NDS were separated in this order and with the water-rich solution, they were separated in the reverse order at the pressure of 5.5 MPa and 20 °C. The phase-separation mode could be performed at the high pressure even at the room temperature.

Indexed as

High pressureHPLCPhase-separation modePhase-separation multiphase flowRoom temperature

Identifiers

PMID39080195

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.