ArticleAnalytical sciences : the international journal of the Japan Society for Analytical Chemistry2024
Development of a HPLC system using a phase-separation multiphase flow as an eluent: an influence of column pressure on phase separation and chromatogram at room temperature.
Article in Analytical sciences : the international journal of the Japan Society for Analytical Chemistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Recent development of surface treatment of polytetrafluoroethylene.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2025Article
- Direct visualization of phase-separation multiphase flow in a silica bead-packed microchannel using fluorescence microscopy.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We have developed a HPLC system where phase-separation multiphase flow works in the separation column as an eluent. We call the novel separation mechanism a phase-separation mode. The ternary mixed solution of water/acetonitrile/ethyl acetate, which is one of the two-phase-separation mixed solutions, caused the phase-separation multiphase flow via phase change from homogeneous to heterogeneous with the temperature effect (from 20 to 0 °C). In this study, we tried to perform phase-separation multiphase flow with the pressure effect instead of the temperature one. The fused-silica capillary tube (50 cm length and 50 µm inner diameter) was allied to the downstream of the column to apply the pressure of 5.5 MPa to the system. Model analytes of 2,6-naphthalenedisulfonic acid (2,6-NDS) and 1-naphthol (1-NA) were examined. For example, solutions (the volume% of water/acetonitrile/ethyl acetate; 20:55:25, organic-rich) and (60:30:10, water-rich) were used as eluent. The model analytes were not separated with both solutions at the pressure of 1.5 MPa and 20 °C. But with the organic-rich solution, 1-NA and 2,6-NDS were separated in this order and with the water-rich solution, they were separated in the reverse order at the pressure of 5.5 MPa and 20 °C. The phase-separation mode could be performed at the high pressure even at the room temperature.
Indexed as
Identifiers
39080195What OpenQuestion holds
Registered trials