Evidence map›Paper›PMID 39079600›Full record

ArticleJournal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance2024

Clinical utility of a rapid two-dimensional balanced steady-state free precession sequence with deep learning reconstruction.

Katerina Eyre, Moezedin Javad Rafiee, Margherita Leo, Junjie Ma, Elizabeth Hillier, Negin Amini, Josephine Pressacco, Martin A Janich, Xucheng Zhu, Matthias G Friedrich and 1 more

Abstract readComparative Study
In one paragraph

Article in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Clinical feasibility of two cardiac deep learning cine magnetic resonance imaging sequences: Single-breath-hold and free-breathing motion-corrected approaches.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2025
    Article
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Katerina EyreResearch Institute, McGill University Health Centre, Montreal, Quebec, Canada. Electronic address: katerina.eyre@muhc.mcgill.ca.
Moezedin Javad RafieeResearch Institute, McGill University Health Centre, Montreal, Quebec, Canada.
Margherita LeoResearch Institute, McGill University Health Centre, Montreal, Quebec, Canada.
Junjie MaGE HealthCare, Milwaukee, Wisconsin, USA.
Elizabeth HillierResearch Institute, McGill University Health Centre, Montreal, Quebec, Canada.
Negin AminiResearch Institute, McGill University Health Centre, Montreal, Quebec, Canada.
Josephine PressaccoDepartment of Diagnostic Radiology, McGill University, Montreal, Quebec, Canada.
Martin A JanichGE HealthCare, Milwaukee, Wisconsin, USA.
Xucheng ZhuGE HealthCare, Milwaukee, Wisconsin, USA.
Matthias G FriedrichResearch Institute, McGill University Health Centre, Montreal, Quebec, Canada; Area19 Medical Inc., Montreal, Canada; Division of Cardiology, McGill University, Montreal, Quebec, Canada.
Michael ChetritResearch Institute, McGill University Health Centre, Montreal, Quebec, Canada; Division of Cardiology, McGill University, Montreal, Quebec, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCardiovascular magnetic resonance (CMR) cine imaging is still limited by long acquisition times. This study evaluated the clinical utility of an accelerated two-dimensional (2D) cine sequence with deep learning reconstruction (Sonic DL) to decrease acquisition time without compromising quantitative volumetry or image quality.

methodsA sub-study using 16 participants was performed using Sonic DL at two different acceleration factors (8× and 12×). Quantitative left-ventricular volumetry, function, and mass measurements were compared between the two acceleration factors against a standard cine method. Following this sub-study, 108 participants were prospectively recruited and imaged using a standard cine method and the Sonic DL method with the acceleration factor that more closely matched the reference method. Two experienced clinical readers rated images based on their diagnostic utility and performed all image contouring. Quantitative contrast difference and endocardial border sharpness were also assessed. Left- and right-ventricular volumetry, left-ventricular mass, and myocardial strain measurements were compared between cine methods using Bland-Altman plots, Pearson's correlation, and paired t-tests. Comparative analysis of image quality was measured using Wilcoxon-signed-rank tests and visualized using bar graphs.

resultsSonic DL at an acceleration factor of 8 more closely matched the reference cine method. There were no significant differences found across left ventricular volumetry, function, or mass measurements. In contrast, an acceleration factor of 12 resulted in a 6% (5.51/90.16) reduction of measured ejection fraction when compared to the standard cine method and a 4% (4.32/88.98) reduction of measured ejection fraction when compared to Sonic DL at an acceleration factor of 8. Thus, Sonic DL at an acceleration factor of 8 was chosen for downstream analysis. In the larger cohort, this accelerated cine sequence was successfully performed in all participants and significantly reduced the acquisition time of cine images compared to the standard 2D method (reduction of 37% (5.98/16) p < 0.0001). Diagnostic image quality ratings and quantitative image quality evaluations were statistically not different between the two methods (p > 0.05). Left- and right-ventricular volumetry and circumferential and radial strain were also similar between methods (p > 0.05) but left-ventricular mass and longitudinal strain were over-estimated using the proposed accelerated cine method (mass over-estimated by 3.36 g/m

conclusionThis study found that an accelerated 2D cine method with DL reconstruction at an acceleration factor of 8 can reduce CMR cine acquisition time by 37% (5.98/16) without significantly affecting volumetry or image quality. Given the increase of scan time efficiency, this undersampled acquisition method using deep learning reconstruction should be considered for routine clinical CMR.

Indexed as

Deep LearningImage Interpretation, Computer-AssistedMagnetic Resonance Imaging, CinePredictive Value of TestsVentricular Function, LeftAdultAgedFemaleHeart VentriclesHumansMaleMiddle AgedObserver VariationProspective StudiesReproducibility of ResultsStroke VolumeAccelerated imagingCardiac functionClinical utilityCMRDeep learning reconstructionDiagnostic accuracy

Identifiers

PMID39079600
PMCPMC11367510

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.