SynthesisEuropace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology2024
Same-day discharge vs. overnight stay following catheter ablation for atrial fibrillation: a comprehensive review and meta-analysis by the European Heart Rhythm Association Health Economics Committee.
Synthesis in Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers, 3 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
22 citing papers in PubMed, 3 syntheses or guidelines pooled it.
- Pulsed field ablation for the interventional treatment of atrial fibrillation: a scientific statement of the European Heart Rhythm Association of the European Society of Cardiology, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, the Latin American Heart Rhythm Society, and the Canadian Heart Rhythm Society.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026Guideline
- Safety and efficacy of intracardiac echocardiography in atrial fibrillation ablation: a meta-analysis.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026Pooled it
- Economic Evaluations in Electrophysiology in the Last 15 Years: A Systematic Review of the Literature.Reviews in cardiovascular medicine · 2025Pooled it
- Procedural characteristics and clinical outcomes from same-day discharge after pulsed field ablation treatment for atrial fibrillation: an admIRE trial sub-analysis.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025Trial
- Improved patient value after implementing same day discharge for patients undergoing pulmonary vein isolation.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026Article
- [Position paper of the German Society of Cardiology-quality criteria for performing catheter ablation of atrial fibrillation: executive summary].Herzschrittmachertherapie & Elektrophysiologie · 2026Article
- [The EHRA/HRS/APHRS/LAHRS/AEPC consensus statement on the management of atrial tachycardias : Implications of the SMART-AT 10-point plan for clinical practice and healthcare structures].Herzschrittmachertherapie & Elektrophysiologie · 2026Article
- Sedation Strategies, Drugs, and Protocols Used in Catheter Ablation of Atrial Fibrillation: A Focused Review.Reviews in cardiovascular medicine · 2026Review
- Delayed coronary vasospasm after pulsed field ablation for pulmonary vein isolation despite avoidance of coronary-adjacent ablation sites.HeartRhythm case reports · 2026Article
- Same day discharge can be performed safely after atrial fibrillation catheter ablation using a wide-footprint lattice-tip dual-energy system.Heart rhythm O2 · 2026Article
- Pulsed field ablation: from technological breakthrough to structured clinical implementation-the role of the European Heart Rhythm Association.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026Article
- Same-day discharge after electrophysiological and cardiac implantable electronic device procedures: a clinical consensus statement of the European Heart Rhythm Association (EHRA) and the Association of Cardiovascular Nursing & Allied Professions (ACNAP) of the ESC.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026Review
- Same-Day Discharge After Atrial Fibrillation Ablation. A Scoping Review of Nurse-Led Care Model.Health science reports · 2026Article
- Patient and Procedural Factors Associated With Same-Day Discharge Following Pulsed Field Ablation for Atrial Fibrillation: Insights From the DISRUPT-AF Registry.Journal of cardiovascular electrophysiology · 2026Observational
- Controversy: pulsed field ablation is the standard technique for all the candidates for atrial fibrillation ablation.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025Review
- Transforming atrial fibrillation management by targeting comorbidities and reducing atrial fibrillation burden: the 10th AFNET/EHRA consensus conference.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025Article
- A day off to admIRE: same-day discharge after pulsed field ablation with a Variable-loop circular catheter.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025Article
- Underexplored energy reduction, posterior dosing constraints, and bundling effects in the PeAF-by-LAWT trial.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025Article
- Vascular access site management during electrophysiology procedures: a European Heart Rhythm Association survey.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025Article
- Same-Day Discharge: It's Not Always Better to Sleep Over.Journal of the American Heart Association · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
aimsSame-day discharge (SDD) after catheter ablation of atrial fibrillation (AF) may address the growing socio-economic health burden of the increasing demand for interventional AF therapies. This systematic review and meta-analysis analyses the current evidence on clinical outcomes in SDD after AF ablation compared with overnight stay (ONS). METHODS AND
resultsA systematic search of the PubMed database was performed. Pre-defined endpoints were complications at short-term (24-96 h) and 30-day post-discharge, re-hospitalization, and/or emergency room (ER) visits at 30-day post-discharge, and 30-day mortality. Twenty-four studies (154 716 patients) were included. Random-effects models were applied for meta-analyses of pooled endpoint prevalence in the SDD cohort and for comparison between SDD and ONS cohorts. Pooled estimates for complications after SDD were low both for short-term [2%; 95% confidence interval (CI): 1-5%; I2: 89%) and 30-day follow-up (2%; 95% CI: 1-4%; I2: 91%). There was no significant difference in complications rates between SDD and ONS [short-term: risk ratio (RR): 1.62; 95% CI: 0.52-5.01; I2: 37%; 30 days: RR: 0.65; 95% CI: 0.42-1.00; I2: 95%). Pooled rates of re-hospitalization/ER visits after SDD were 4% (95% CI: 1-10%; I2: 96%) with no statistically significant difference between SDD and ONS (RR: 0.86; 95% CI: 0.58-1.27; I2: 61%). Pooled 30-day mortality was low after SDD (0%; 95% CI: 0-1%; I2: 33%). All studies were subject to a relevant risk of bias, mainly due to study design.
conclusionIn this meta-analysis including a large contemporary cohort, SDD after AF ablation was associated with low prevalence of post-discharge complications, re-hospitalizations/ER visits and mortality, and a similar risk compared with ONS. Due to limited quality of current evidence, further prospective, randomized trials are needed to confirm safety of SDD and define patient- and procedure-related prerequisites for successful and safe SDD strategies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.