Evidence map›Paper›PMID 39077657›Full record

ArticleReviews in cardiovascular medicine2024

Patient Characteristics and Outcomes Associated with Sentinel Protection Device Use in Patients with Aortic Valve Disease Undergoing TAVR in a "Real-World" Setting.

Habib Jabagi, Richard E Shaw, Lara Gharibeh, Rajiv Tayal, Hussein Rahim, Francis Kim, Alex Zapolanski, Juan B Grau

Abstract read
In one paragraph

Article in Reviews in cardiovascular medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Habib JabagiDivision of Cardiothoracic Surgery, The Valley Hospital, Ridgewood, NJ 07450, USA.
Richard E ShawDivision of Cardiothoracic Surgery, The Valley Hospital, Ridgewood, NJ 07450, USA.
Lara GharibehDepartment of Biochemistry, Microbiology and Immunology, University of Ottawa, Ottawa, ON K1Y 4W7, Canada.
Rajiv TayalDivision of Interventional Cardiology, The Valley Hospital, Ridgewood, NJ 07450, USA.
Hussein RahimDivision of Interventional Cardiology, The Valley Hospital, Ridgewood, NJ 07450, USA.
Francis KimDivision of Interventional Cardiology, The Valley Hospital, Ridgewood, NJ 07450, USA.
Alex ZapolanskiDivision of Cardiothoracic Surgery, The Valley Hospital, Ridgewood, NJ 07450, USA.
Juan B GrauDivision of Cardiothoracic Surgery, The Valley Hospital, Ridgewood, NJ 07450, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Transcatheter aortic valve replacement (TAVR) has become the dominant treatment for aortic valve disease. While TAVR safety has improved over time, concern remains over the occurrence of cerebrovascular accidents (CVA) secondary to device placement, which is associated with increased morbidity and mortality. The Sentinel Cerebral Protection System (CPS) was developed to reduce the risk of embolic strokes associated with debris produced during TAVR. Studies evaluating Sentinel CPS efficacy have produced conflicting results, and there is little understanding of which patients are selected for device placement in "real-world" settings. With no existing guidelines on device use, the purpose of this study was to describe and compare the characteristics of patients who receive CPS with those who do not in a "real-world" setting of consecutive TAVR patients and evaluate its impact on postoperative complications, namely stroke. Methods: This was a single-center, retrospective study of all patients undergoing TAVR between July 1, 2019, and December 31, 2020. Patient demographics, baseline, and perioperative characteristics were collected prospectively using the Society of Thoracic Surgeons (STS)/American College of Cardiology (ACC) Transcatheter Valve Therapy (TVT) Registry and our institution's TAVR database for analysis. Postoperative outcomes were assessed using primary endpoints of in-hospital/30-day stroke and the composite of death, stroke, and bleeding/vascular events at one-year. To adjust for baseline differences, a propensity score was developed including all factors that were different between groups, and Multivariate Cox Regression analysis was used to control for these differences. Patient follow-up was 97% complete at 12 months with 100% echocardiographic follow-up. Results: A total of 242 consecutive patients (57.9% male) were analyzed, with a mean age of 79.9 Conclusions: Our study demonstrates that in a "real-world" setting, the Sentinel CPS device is more likely to be used in healthier and less complex patients. In analyses adjusted for illness severity and patient complexity, CPS use did not have a significant effect on the incidence of in-hospital/30-day stroke or the composite endpoint of death, stroke, and bleeding/vascular events at one-year.

Indexed as

aortic valve diseasecerebrovascular accidents (CVA)sentinel cerebral protection system (CPS)stroketranscatheter aortic valve replacement (TAVR)

Identifiers

PMID39077657
PMCPMC11262339

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.