Evidence map›Paper›PMID 39077012›Full record

ArticleReviews in cardiovascular medicine2023

Mid-Term Outcomes of Novel Covered Stent with Biodegradable Membrane in Porcine Coronary Artery Perforation.

Wei Cai, En Chen, Hong Zheng, Danqing Hu, Lingzhen Wu, Xiaoling Zeng, Jinhua Huang, Lianglong Chen

Abstract read
In one paragraph

Article in Reviews in cardiovascular medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. The Pathophysiology of Acute Coronary Syndrome.Reviews in cardiovascular medicine · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Wei CaiDepartment of Cardiology, Fujian Heart Medical Center, Fujian Institute of Coronary Artery Disease, Fujian Institute of Geriatrics, Fujian Medical University Union Hospital, 350001 Fuzhou, Fujian, China.
En ChenDepartment of Cardiology, Fujian Heart Medical Center, Fujian Institute of Coronary Artery Disease, Fujian Institute of Geriatrics, Fujian Medical University Union Hospital, 350001 Fuzhou, Fujian, China.
Hong ZhengDepartment of Cardiology, Fujian Heart Medical Center, Fujian Institute of Coronary Artery Disease, Fujian Institute of Geriatrics, Fujian Medical University Union Hospital, 350001 Fuzhou, Fujian, China.
Danqing HuSchool of Health, Fujian Medical University, 350005 Fuzhou, Fujian, China.
Lingzhen WuDepartment of Cardiology, Fujian Heart Medical Center, Fujian Institute of Coronary Artery Disease, Fujian Institute of Geriatrics, Fujian Medical University Union Hospital, 350001 Fuzhou, Fujian, China.
Xiaoling ZengDepartment of Cardiology, Fujian Heart Medical Center, Fujian Institute of Coronary Artery Disease, Fujian Institute of Geriatrics, Fujian Medical University Union Hospital, 350001 Fuzhou, Fujian, China.
Jinhua HuangDepartment of Cardiology, Fujian Heart Medical Center, Fujian Institute of Coronary Artery Disease, Fujian Institute of Geriatrics, Fujian Medical University Union Hospital, 350001 Fuzhou, Fujian, China.
Lianglong ChenDepartment of Cardiology, Fujian Heart Medical Center, Fujian Institute of Coronary Artery Disease, Fujian Institute of Geriatrics, Fujian Medical University Union Hospital, 350001 Fuzhou, Fujian, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Currently, commercially covered stents are the main treatment for coronary artery perforation (CAP), but without satisfied late-term outcomes when compared to drug-eluting stents (DES). This study seeks to report a new covered stent to treat porcine CAP, which is manufactured with DES and a biodegradable membrane fabricated by poly-L-lactic acid (PLLA) polymer. Methods: Experimental swines experienced CAP in proximal-middle of right coronary artery (RCA) by non-compliant balloon burst, and covered stent was deployed in breach segment. Meanwhile, coronary angiography (CAG), optical coherence tomography (OCT), histological light microscopy and scan electron microscopy were performed to characterize the performance of covered stent. Results: Seven swines were used for this study. Two swines were euthanasia at 14 days and 28 days after procedure, respectively. The remaining 5 kept alive until sacrifice at six months. CAG at six months showed total occlusion at the stented segment of RCA in all swines. The interventional revascularization of occlusion lesion was instituted in two swines. After recanalizing occlusion lesion, OCT examination visualized diffuse heterogeneous fibrous plaques, as well as organized thrombosis, lipid deposits and several neoatherosclerosis in the occluded segment. Serial histopathologic and electron microscopies at 14 days, 28 days and six months revealed gradual occlusive vessel lumen with diffuse heterogeneous fibroplasia, smooth muscle proliferation, inflammation response and local neoatherosclerosis, moreover with identification of PLLA polymer membrane degradability. Conclusions: The new covered stent with biodegradable membrane could seal urgent coronary breach and prevent experimental swines death, but with all stent occlusion in mid-term (six months) follow-up, which might be attributed to diffuse heterogeneous fibroplasia, smooth muscle proliferation, inflammation response and local neoatherosclerosis with the degradation of PLLA membrane.

Indexed as

biodegradable membranecoronary artery perforationcovered stentfibroplasianeoatherosclerosispoly-L-lactic acidporcine

Identifiers

PMID39077012
PMCPMC11266466

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.