Evidence map›Paper›PMID 39076317›Full record

SynthesisReviews in cardiovascular medicine2024

Efficacy and Safety of Laser Balloon Versus Irrigated Radiofrequency Ablation as Initial Therapies for Atrial Fibrillation: A Meta-Analysis.

Fujiang Chen, Donglin Guo, Tiantian Zheng, Yangyang Gu, Xinbin Zhou, Yuangang Qiu, Shuwei Huang, Wenyi Ye

Abstract readSystematic Review
In one paragraph

Synthesis in Reviews in cardiovascular medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Semaglutide as adjunctive therapy to catheter ablation in obesity-related paroxysmal atrial fibrillation.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Fujiang ChenDepartment of Anesthesiology, Shanxi Provincial People's Hospital, 030012 Taiyuan, Shanxi, China.
Donglin GuoDepartment of Clinical Laboratory, Shanxi Provincial People's Hospital, 030012 Taiyuan, Shanxi, China.
Tiantian ZhengThe First College of Clinical Medicine, Zhejiang Chinese Medical University, 310053 Hangzhou, Zhejiang, China.
Yangyang GuThe First College of Clinical Medicine, Zhejiang Chinese Medical University, 310053 Hangzhou, Zhejiang, China.
Xinbin ZhouThe First Affiliated Hospital of Zhejiang Chinese Medical University (Zhejiang Provincial Hospital of Chinese Medicine), 310006 Hangzhou, Zhejiang, China.
Yuangang QiuThe First Affiliated Hospital of Zhejiang Chinese Medical University (Zhejiang Provincial Hospital of Chinese Medicine), 310006 Hangzhou, Zhejiang, China.
Shuwei HuangThe First Affiliated Hospital of Zhejiang Chinese Medical University (Zhejiang Provincial Hospital of Chinese Medicine), 310006 Hangzhou, Zhejiang, China.
Wenyi YeThe First Affiliated Hospital of Zhejiang Chinese Medical University (Zhejiang Provincial Hospital of Chinese Medicine), 310006 Hangzhou, Zhejiang, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Catheter ablation (CA) is an effective therapy for atrial fibrillation (AF) and, although radiofrequency ablation (RFA) is the standard treatment for pulmonary vein isolation (PVI), it is complex and time-consuming. Laser balloon ablation (LBA) has been introduced to simplify the conventional RFA; however, results of studies comparing LBA and RFA remain controversial. As such, this investigation aimed to comprehensively evaluate the efficacy and safety of LBA versus RFA. Methods: The PubMed, Embase, Cochrane Library, and ClinicalTrials.gov databases were searched for relevant studies. The primary endpoints were the freedom from atrial tachyarrhythmia (ATA) and procedure-related complications. Results: Twelve studies including 1274 subjects were included. LBA and RFA yielded similar rates of freedom from ATA (72.5% vs. 68.7%, odds ratio [OR] = 1.26, 95% confidence interval [CI] 1.0-1.7, Conclusions: LBA and RFA treatments were comparable in terms of freedom from ATA and postprocedural complications in patients with AF. Compared with RFA, LBA was associated with significantly lower PV reconnection rates, but a higher incidence of PNP and longer ablation time.

Indexed as

atrial fibrillationcatheter ablationlaser balloon ablationmeta-analysisradiofrequency ablation

Identifiers

PMID39076317
PMCPMC11270124

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked