ArticleFoot & ankle international2024
Five-Year Results of the Salto XT Revision Ankle Arthroplasty.
Article in Foot & ankle international, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Fate of revision total ankle arthroplasty: a meta-analysis of 999 cases.International journal of surgery (London, England) · 2025Pooled it
- Outcomes and associated factors of revision procedures after failed total ankle arthroplasty: a comparative cohort analysis.Archives of orthopaedic and trauma surgery · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe treatment of failed ankle replacements is debated, and little is published about the medium- and long-term results of revision implants. We wanted to examine prosthesis survival and physical function at least 5 years after insertion of the Salto XT revision prosthesis.
methodsAll consecutive patients operated with a Salto XT revision prosthesis underwent clinical and radiologic examinations preoperatively and after 3, 12, 24, and 60 months. Complications and reoperations are described, and changes in patient-reported outcome measures and clinical scores are reported.
resultsThirty patients were operated with a Salto XT revision prosthesis between March 2014 and March 2017. Three of these were revised (1 to a fusion and 2 to a new prosthesis), and 3 patients were reoperated with screw removal. A concurrent subtalar fusion was performed on 13 patients, and there was 1 case of likely nonunion after these procedures, but no reoperations. The mean AOFAS score increased from 39.2 (95% CI 30.8-47.5) preoperatively to 75.1 (95% CI 67.3-82.9) after 5 years, and the mean improvement was 34.2 points (95% CI 23.8-44.6). Mean EQ-5D increased from 0.36 (95% CI 0.30-0.42) preoperatively to 0.74 (95% CI 0.64-0.85) after 5 years, an improvement of 0.34 (95% CI 0.19-0.49). Radiolucent lines were present in all but 3 patients. Five-year prosthesis survival was 93% (83.6-100).
conclusionThis is the first study to present medium-term results of this implant. We found good improvement in outcome scores and good implant survival, but also a high prevalence of radiolucent lines.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.