Evidence map›Paper›PMID 39075599›Full record

ArticleJournal of orthopaedic surgery and research2024

Clinical efficacy of arthroscopic high-intensity suture binding combined with button plate suspension fixation in the treatment of posterior cruciate ligament tibial avulsion fractures.

Pei Zhang, Wenkang Liu, Pengtao Chen, Wenyong Fei, Hansheng Hu, Dan Wen

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. [Arthroscopic treatment of posterior cruciate ligament tibial insertion avulsion fractures using a four-leaf clover-shaped titanium plate combined with an adjustable loop].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2026
    Article
  2. [Posterior open approach combined with suture bridge technique for tibial insertion avulsion fractures of posterior cruciate ligament].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2026
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Pei Zhang *Department of Orthopedics and Sports Medicine, Northern Jiangsu People's Hospital, Yangzhou, 225001, P. R. China.
Wenkang Liu *Department of Orthopedics and Sports Medicine, Northern Jiangsu People's Hospital, Yangzhou, 225001, P. R. China.
Pengtao ChenDepartment of Orthopedics and Sports Medicine, Northern Jiangsu People's Hospital, Yangzhou, 225001, P. R. China.
Wenyong FeiDepartment of Orthopedics and Sports Medicine, Northern Jiangsu People's Hospital, Yangzhou, 225001, P. R. China.
Hansheng HuDepartment of Orthopedics and Sports Medicine, Northern Jiangsu People's Hospital, Yangzhou, 225001, P. R. China.
Dan WenDepartment of Orthopedics and Sports Medicine, Northern Jiangsu People's Hospital, Yangzhou, 225001, P. R. China. DrWenDan@126.com.

Funding

the clinical application-oriented medical innovation 2021-NCRC-CXJJ-PY-07the Scientific research project of Jiangsu Provincial Health and Health Commission M2021042the Yangzhou social development project YZ2021084
6 · The paper itself

Abstract

purposeTo assess the clinical efficacy of arthroscopic treatment for posterior cruciate ligament (PCL) tibial avulsion fractures using high-intensity suture binding combined with button plate suspension fixation.

methodsWe retrospectively analyzed clinical data from 32 patients with PCL tibial avulsion fractures treated at our hospital from July 2020 to August 2023. We recorded operation time, intraoperative and postoperative complications, and used imaging to assess fracture reduction and healing. Pain and knee function were evaluated using the Visual Analogue Scale (VAS), range of knee motion, Lysholm score, and International Knee Documentation Committee (IKDC) score. STUDY

designCase series; Level of evidence, 4.

resultsAll patients were followed for 6 to 18 months, averaging 13.6 months. All incisions healed successfully without postoperative complications. X-rays taken on the first postoperative day showed satisfactory fracture reduction. Three-month post-surgery imaging confirmed healed fractures and no internal fixation failures. At the final follow-up, knee function was well recovered, with only one patient exhibiting a positive posterior drawer test of degree I. Furthermore, the mean VAS score was 0. 5 (range 0.0 to 1.0), active knee extension was 2. 2° (range 0.0 to 5.0), and active knee flexion was 137.7° (range 130.0 to 145.0). The mean Lysholm score was 91.5(range 89.3 to 94.0), and the IKDC score averaged 83.8 ± 3.7, and these outcomes showed statistically significant improvement from preoperative levels (P < 0.001).

conclusionsArthroscopic high-intensity suture binding combined with button plate suspension fixation for PCL tibial avulsion fractures offers several benefits: it is minimally invasive, results in less postoperative pain, enables earlier functional exercise, and provides satisfactory clinical outcomes with fewer complications.

Indexed as

ArthroscopyBone PlatesFracture Fixation, InternalFractures, AvulsionPosterior Cruciate LigamentTibial FracturesAdultFemaleFollow-Up StudiesHumansMaleMiddle AgedRange of Motion, ArticularRetrospective StudiesSuture TechniquesTreatment OutcomeArthroscopyAvulsion fracturesButton plate fixationPosterior cruciate ligamentSuture fixation

Identifiers

PMID39075599
PMCPMC11285257

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.