Evidence map›Paper›PMID 39072220›Full record

ArticleJournal of medical imaging (Bellingham, Wash.)2024

Impact of patient habitus and acquisition protocol on iodine quantification in dual-source photon-counting computed tomography.

Leening P Liu, Rizza Pua, Michael Dieckmeyer, Nadav Shapira, Pooyan Sahbaee, Grace J Gang, Harold I Litt, Peter B Noël

Abstract read
In one paragraph

Article in Journal of medical imaging (Bellingham, Wash.), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Leening P LiuUniversity of Pennsylvania, Perelman School of Medicine, Department of Radiology, Philadelphia, Pennsylvania, United States.ORCID https://orcid.org/0000-0003-0560-5394
Rizza PuaUniversity of Pennsylvania, Perelman School of Medicine, Department of Radiology, Philadelphia, Pennsylvania, United States.
Michael DieckmeyerUniversity of Pennsylvania, Perelman School of Medicine, Department of Radiology, Philadelphia, Pennsylvania, United States.
Nadav ShapiraUniversity of Pennsylvania, Perelman School of Medicine, Department of Radiology, Philadelphia, Pennsylvania, United States.ORCID https://orcid.org/0000-0002-9294-7001
Pooyan SahbaeeSiemens Medical Solutions, Malvern, Pennsylvania, United States.
Grace J GangUniversity of Pennsylvania, Perelman School of Medicine, Department of Radiology, Philadelphia, Pennsylvania, United States.ORCID https://orcid.org/0000-0002-3882-0210
Harold I LittUniversity of Pennsylvania, Perelman School of Medicine, Department of Radiology, Philadelphia, Pennsylvania, United States.
Peter B NoëlUniversity of Pennsylvania, Perelman School of Medicine, Department of Radiology, Philadelphia, Pennsylvania, United States.ORCID https://orcid.org/0000-0002-9671-6171

Funding

Patient-specific, high-sensitivity spectral CT for assessment of pancreatic cancerR01EB030494 · NIBIB · UNIVERSITY OF PENNSYLVANIA · PI GANG, JIANAN GRACE, NOËL, PETER B · 2021 to 2024
$2.4M
NIBIB NIH HHS R01 EB030494
6 · The paper itself

Abstract

Purpose: Evaluation of iodine quantification accuracy with varying iterative reconstruction level, patient habitus, and acquisition mode on a first-generation dual-source photon-counting computed tomography (PCCT) system. Approach: A multi-energy CT phantom with and without its extension ring equipped with various iodine inserts (0.2 to 15.0 mg/ml) was scanned over a range of radiation dose levels ( Results: Overall, quantification of iodine concentrations was accurate and reliable even at ultra-low radiation dose levels. RMSE ranged from 0.25 to 0.37, 0.20 to 0.38, and 0.25 to 0.37 mg/ml for ultra-low, low, and medium radiation dose levels, respectively. Similarly, RMSE was stable at 0.31, 0.28, 0.33, and 0.30 mg/ml for tube voltage and source mode combinations. Ultimately, the accuracy of iodine quantification was higher for the phantom without an extension ring (RMSE 0.21 mg/mL) and did not vary across different levels of iterative reconstruction. Conclusions: The first-generation PCCT allows for accurate iodine quantification over a wide range of iodine concentrations and radiation dose levels. Stable accuracy across iterative reconstruction levels may allow further radiation exposure reductions without affecting quantitative results.

Indexed as

computed tomographydiagnostic imagingiodine quantificationphoton-counting computed tomographyradiation dosage

Identifiers

PMID39072220
PMCPMC11278921

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.