Evidence map›Paper›PMID 39071769›Full record

ArticlePlastic and reconstructive surgery. Global open2024

Perfusion Mapping of Flaps Using Indocyanine Green Fluorescence Angiography and Laser Speckle Contrast Imaging.

Johan Zötterman, Erik Tesselaar, Sherif Elawa, Moustafa Elmasry, Simon Farnebo

Abstract read
In one paragraph

Article in Plastic and reconstructive surgery. Global open, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Johan ZöttermanFrom the Department of Hand and Plastic Surgery and Burns and Department of Clinical and Experimental Medicine, Linköping University, Linköping, Sweden.
Erik TesselaarDepartment of Medical Radiation Physics and Department of Clinical and Experimental Medicine, Linköping University, Linköping, Sweden.
Sherif ElawaFrom the Department of Hand and Plastic Surgery and Burns and Department of Clinical and Experimental Medicine, Linköping University, Linköping, Sweden.
Moustafa ElmasryFrom the Department of Hand and Plastic Surgery and Burns and Department of Clinical and Experimental Medicine, Linköping University, Linköping, Sweden.
Simon FarneboFrom the Department of Hand and Plastic Surgery and Burns and Department of Clinical and Experimental Medicine, Linköping University, Linköping, Sweden.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Indocyanine green fluorescence angiography (ICG-FA) is often used for assessing tissue circulation in reconstructive surgery. Indocyanine green (ICG) is injected intravenously and visualized in the tissue with an infrared camera. The information is used to plan the surgery, for example, in free flap breast reconstructions. Laser speckle contrast imaging (LSCI) is another method that uses laser to assess tissue perfusion in the skin. Unlike ICG-FA, LSCI is noninvasive and may therefore have an advantaged compared with ICG-FA. The aim of this study was to evaluate the correlation between information obtained from these two techniques. Methods: Five deep inferior epigastric perforator patients were included. The flaps were assessed with LSCI and ICG-FA. For LSCI, the perfusion was calculated in 32 regions of interest. For ICG-FA, the maximum slope and area under curve (AUC) were calculated based on average pixel intensity data. Results: Large variations in maximum slope values could be seen between flaps, whereas AUC had lower variability within the same flap and between flaps. Pearson rank correlation comparing average perfusion (LSCI) and AUC (ICG-FA) showed a correlation between the values (r = 0.55, Conclusions: There is a significant correlation between data obtained using LSCI and ICG-FA, when ICG-FA data are presented as AUC of the ICG-FA intensity curve. Maximum slope lacks significant correlation with flap data obtained with LSCI. The study indicates that LSCI may be used in reconstructive surgery to assess tissue circulation in a way similar to ICG-FA.

Identifiers

PMID39071769
PMCPMC11281778

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked