Evidence map›Paper›PMID 39071093›Full record

ArticleArthroplasty today2024

Surgeon-Applied Stress and a Ligament Tensor Instrument Provide a Similar Assessment of Preresection Flexion Laxity During Robotic Total Knee Arthroplasty.

Catelyn A Woelfle, Travis R Weiner, Peter K Sculco, Nana O Sarpong, Roshan P Shah, H John Cooper

Abstract read
In one paragraph

Article in Arthroplasty today, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Trial
  4. Article
  5. Article
  6. Article
  7. Review
  8. Review
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Catelyn A WoelfleDepartment of Orthopedic Surgery, New York Presbyterian Hospital - Columbia University Irving Medical Center, New York, NY, USA.
Travis R WeinerDepartment of Orthopedic Surgery, New York Presbyterian Hospital - Columbia University Irving Medical Center, New York, NY, USA.
Peter K SculcoDepartment of Orthopedic Surgery, Hospital for Special Surgery, New York, NY, USA.
Nana O SarpongDepartment of Orthopedic Surgery, New York Presbyterian Hospital - Columbia University Irving Medical Center, New York, NY, USA.
Roshan P ShahDepartment of Orthopedic Surgery, New York Presbyterian Hospital - Columbia University Irving Medical Center, New York, NY, USA.
H John CooperDepartment of Orthopedic Surgery, New York Presbyterian Hospital - Columbia University Irving Medical Center, New York, NY, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Robotic-assisted total knee arthroplasty (RA-TKA) allows surgeons to perform intraoperative soft tissue laxity assessments prior to bone resections and is used to alter resections to achieve gap balance. This study compared 2 techniques for flexion gap laxity assessment during RA-TKA. Methods: A prospective study of 50 primary RA-TKAs performed by a single surgeon was conducted between February and October 2023. Following full exposure, anterior tibial dislocation, and osteophyte removal, maximal medial and lateral compartment flexion laxity was quantified to the nearest 0.5 mm by the robotic system using a dynamic, surgeon-applied stress (SURGEON). This data was used to plan a balanced flexion gap by adjusting the femoral component size, rotation, and anterior-posterior translation. Flexion laxity was quantified again after distal femoral and proximal tibial resections using a ligament tensor instrument (TENSOR). These new data were used to plan for the same desired flexion gap using the same variables. Paired-samples Results: Both methods produced near-identical recommendations for femoral component sizing (mean deviation 0.06 sizes, range -1 to +1 size; Conclusions: Assessing flexion laxity with a surgeon-applied stress vs a ligament tensor produced near-identical laxity data in RA-TKA, suggesting surgeons may comfortably choose either technique as a reliable method. Level of Evidence: Level III.

Indexed as

Flexion laxityGap balancingRobotic-assisted total knee arthroplasty (RA-TKA)Total knee arthroplasty (TKA)

Identifiers

PMID39071093
PMCPMC11283011

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked