Evidence map›Paper›PMID 39069988›Full record

ArticleIEEE transactions on radiation and plasma medical sciences2024

Effect of detector placement on joint estimation in X-ray fluorescence emission tomography.

Hadley DeBrosse, Ling Jian Meng, Patrick La Rivière

Abstract read
In one paragraph

Article in IEEE transactions on radiation and plasma medical sciences, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Hadley DeBrosseDepartment of Radiology, University of Chicago, Chicago, IL.
Ling Jian MengDepartment of Nuclear, Plasma, and Radiological Engineering, University of Illinois Urbana-Champaign, Urbana, IL.
Patrick La RivièreDepartment of Radiology, University of Chicago, Chicago, IL.

Funding

VIRAL ONCOLOGY CORE FACILITYP30CA014599 · NCI · UNIVERSITY OF CHICAGO · PI MARK W. LINGEN · 1985 to 2026
$122.1M
Broadband X-ray Fluorescence Emission TomographyR01EB026300 · NIBIB · UNIVERSITY OF ILLINOIS AT URBANA-CHAMPAIGN · PI LA RIVIERE, PATRICK JEAN, LU, YI · 2018 to 2021
$2.4M
Protected Radiomics Analysis Commons for Deep Learning in Biomedical DiscoveryS10OD025081 · OD · UNIVERSITY OF CHICAGO · PI GIGER, MARYELLEN L. · 2018 to 2018
$339k
High-Performance Computer Cluster for Image AnalysisS10RR021039 · NCRR · UNIVERSITY OF CHICAGO · PI NISHIKAWA, ROBERT M · 2007 to 2007
$230k
X-ray fluorescence emission tomography for imaging trace gold in mouse modelsF31CA275324 · NCI · UNIVERSITY OF CHICAGO · PI DEBROSSE, HADLEY ANNA · 2023 to 2024
$78k
NCI NIH HHS F31 CA275324NCI NIH HHS P30 CA014599NCRR NIH HHS S10 RR021039NIBIB NIH HHS R01 EB026300NIH HHS S10 OD025081
6 · The paper itself

Abstract

Imaging the spatial distribution of low concentrations of metal is a growing problem of interest with applications in medical and material sciences. X-ray fluorescence emission tomography (XFET) is an emerging metal mapping imaging modality with potential sensitivity improvements and practical advantages over other methods. However, XFET detector placement must first be optimized to ensure accurate metal density quantification and adequate spatial resolution. In this work, we first use singular value decomposition of the imaging model and eigendecomposition of the object-specific Fisher information matrix to study how detector arrangement affects spatial resolution and feature preservation. We then perform joint image reconstructions of a numerical gold phantom. For this phantom, we show that two parallel detectors provide metal quantification with similar accuracy to four detectors, despite the resulting anisotropic spatial resolution in the attenuation map estimate. Two orthogonal detectors provide improved spatial resolution along one axis, but underestimate the metal concentration in distant regions. Therefore, this work demonstrates the minor effect of using fewer, but strategically placed, detectors in the case where detector placement is restricted. This work is a critical investigation into the limitations and capabilities of XFET prior to its translation to preclinical and benchtop uses.

Indexed as

EigendecompositionFisher informationjoint estimationSingular value decompositionX-ray fluorescence emission tomography

Identifiers

PMID39069988
PMCPMC11281267

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.