ArticleJournal of orthopaedic surgery and research2024
Biomechanical analysis of patient specific cone vs conventional stem in revision total knee arthroplasty.
Article in Journal of orthopaedic surgery and research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- Managing large type 2a bone defects from osteoporotic tibial plateau fractures : a finite element analysis.Bone & joint research · 2026Article
- Biomechanical analysis of surgical alignment and design in total knee arthroplasty.Archives of orthopaedic and trauma surgery · 2026Article
- Biomechanical evaluation of asymmetric metaphyseal cone applications for lateral tibial plateau fractures : a finite element study.Bone & joint research · 2025Article
- Effects of personalized 3D-printed blocks in total knee arthroplasty and revision surgery for massive bone defects: a single-center retrospective study.The Journal of international medical research · 2025Article
- Optimising tibial extension stem selection in total knee arthroplasty: the role of digital modelling.Frontiers in bioengineering and biotechnology · 2025Article
- Effect of design and surgical parameters variations in mobile-bearing versus fixed-bearing unicompartmental knee arthroplasty: A finite element analysis.Journal of experimental orthopaedics · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
backgroundIn revision total knee arthroplasty, addressing significant bone loss often involves the use of cemented or press-fit stems to ensure implant stability and long-term fixation. A possible alternative to stem was recently introduced utilizing custom-made porous metaphyseal cones, designed to reconstruct the missing tibial and femoral geometries. Early clinical and radiological assessments have shown promising results. The objective of this research was to biomechanically evaluate the performances of these custom-made cones.
methodsThe biomechanical study was conducted using a validated finite element model. The bone geometries of a patient (selected for their history of four knee revisions due to infection and periprosthetic fractures, followed by a successful treatment with custom-made 3D-printed metaphyseal cones) were employed for the study. On these bone models, different revision scenarios were simulated and examined biomechanically: (A) custom-made cementless metaphyseal cones; (B) cemented stems; (C) press-fit stems; (D) distal femoral reconstruction with press-fit stem. All the models were analyzed at 0 °and 90 °of flexion, under physiological load conditions simulating daily activities; stress distribution, average Von-Mises stresses and risk of fracture were then analyzed and compared among configurations.
resultsThe use of custom-made 3D-printed cones exhibited the most favorable stress distribution in both femoral and tibial bones. Tibial bone stress was evenly distributed in custom-made cone configurations, while stress concentration was observed in distal regions for the other scenarios. Additionally, custom-made cones displayed overall homogeneity and lower stress levels, potentially contributing to limit pain. Symmetrical stress distribution was observed between the lateral and medial proximal tibia in custom-made cone models, whereas other scenarios exhibited uneven stress, particularly in the anterior tibial bone.
conclusionsThe biomechanical analysis of porous custom-made metaphyseal cones in re-revision arthroplasties is in agreement with the positive clinical and radiological outcomes. These findings provide valuable insights into the potential benefits of using custom-made cones, which offer more uniform stress distribution and may contribute to improve patient outcomes in revision TKA procedures. Further studies in this direction are warranted to validate these biomechanical findings.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.