Evidence map›Paper›PMID 39066984›Full record

ArticleJapanese journal of radiology2024

Development of Acceptable Quality Dose (AQD) and image quality-related diagnostic reference levels for common computed tomography investigations in a tertiary care public sector hospital of Khyber Pakhtunkhwa, Pakistan.

Muhammad Yaseen, Tahira Nishtar, Mohammad Hassan Kharita, Banaras Khan, Shady AlKhazzam, Amir Ali, Laila Khan, Nasreen Aman, Shamsullah Burki, Nosheen Noor and 1 more

Abstract read
In one paragraph

Article in Japanese journal of radiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Muhammad YaseenDepartment of Radiology, Lady Reading Hospital-MTI, Peshawar, Pakistan.
Tahira NishtarDepartment of Radiology, Lady Reading Hospital-MTI, Peshawar, Pakistan.
Mohammad Hassan KharitaDepartment of Occupational Health and Safety, Medical Physics Section, Hamad Medical Corporation, Doha, Qatar.
Banaras KhanDepartment of Physics, Qurtuba University of Science and IT, Peshawar, Pakistan.
Shady AlKhazzamDepartment of Occupational Health and Safety, Medical Physics Section, Hamad Medical Corporation, Doha, Qatar. salkhazzam@hamad.qa.ORCID http://orcid.org/0000-0003-3750-3683
Amir AliDepartment of Radiology, Lady Reading Hospital-MTI, Peshawar, Pakistan.
Laila KhanDepartment of Radiology, Lady Reading Hospital-MTI, Peshawar, Pakistan.
Nasreen AmanDepartment of Radiology, Lady Reading Hospital-MTI, Peshawar, Pakistan.
Shamsullah BurkiDepartment of Radiology, Lady Reading Hospital-MTI, Peshawar, Pakistan.
Nosheen NoorDepartment of Radiology, Lady Reading Hospital-MTI, Peshawar, Pakistan.
NabiullahDepartment of Radiology, Lady Reading Hospital-MTI, Peshawar, Pakistan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo describe the first experience of patient dose optimization in developing AQD, SSDE and image quality-related DRLs for common CT examinations in the adult age group using the concept of AQD. MATERIALS AND

methodsThe recent published IQSC from 0 to 4 were used by radiologists for the assessment of image quality. The entire data were collected for five types (brain CT, chest CT, chest HRCT, abdomen KUB CT and abdomen + pelvic CT) CT investigations based on anatomic region (head, chest and abdomen + pelvic). The entire datasets of 264 patients were categorized into three groups based on their weights: group-1 (41-60 kg), group-2 (61-80 kg) and group-3 (81-100 kg). Only score-3 images were considered to assess median and 75th percentile values of CTDI

resultsFollowing the practical training of four radiologists on image quality scoring criteria for CT images, 264 (92%) out of 288 patient images were clinically acceptable as per IQSC for the study. The AQD (median) values in terms of CTDI

conclusionThe first ever experience in obtaining AQD, SSDE and DRLs values for specific CT procedures couples image quality with dose indices, showing comparable values with other relevant studies. Hence, it will provide a baseline for comparison within the facility for future studies and facilitate dose optimization for other facilities aiming for improvement.

Indexed as

Radiation DosageTomography, X-Ray ComputedAdultAgedAged, 80 and overDiagnostic Reference LevelsFemaleHospitals, PublicHumansMaleMiddle AgedPakistanTertiary Care CentersTertiary Health CareYoung AdultAbdomen CTAcceptable Quality Dose (AQD)Chest CTComputed tomography (CT)Diagnostic reference levels (DRLs)

Identifiers

PMID39066984
PMCPMC11588805

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.