ArticleJournal of clinical monitoring and computing2025

Comparison of continuous temperature measurement methods in the intensive care unit: standard bladder catheter measurements versus non-invasive transcutaneous sensors.

Ulrike Elisabeth Ehlers, Jens Ulmer, Mirja Keller, Carsten Klein, Urs Pietsch

Abstract readComparative Study
In one paragraph

Article in Journal of clinical monitoring and computing, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ulrike Elisabeth EhlersDivision of Perioperative Intensive Care Medicine, Cantonal Hospital St. Gallen, Rorschacher Str. 95, St. Gallen, 9007, Switzerland. ulrike.ehlers@kssg.ch.ORCID 0000-0002-2545-598X
Jens UlmerInstitute for Microtechnology and Photonics, Eastern Switzerland University of Applied Science, Werdenbergstr. 4, Buchs, 9471, Switzerland.
Mirja KellerDivision of Perioperative Intensive Care Medicine, Cantonal Hospital St. Gallen, Rorschacher Str. 95, St. Gallen, 9007, Switzerland.
Carsten KleinDivision of Perioperative Intensive Care Medicine, Cantonal Hospital St. Gallen, Rorschacher Str. 95, St. Gallen, 9007, Switzerland.
Urs PietschDivision of Perioperative Intensive Care Medicine, Cantonal Hospital St. Gallen, Rorschacher Str. 95, St. Gallen, 9007, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The purpose of this study was to compare a wearable system for body core temperature measurement versus bladder and tympanic thermometers in an intensive care setting. The question was, if continuous non-invasive sensors in the intensive care unit represent an alternative to current standard methods of invasive continuous bladder temperature measurement methods?Between May and September 2023, a comparative investigation involving 112 patients was conducted in a 20-bed surgical intensive care unit to assess various temperature probes, including those placed in the tympanic tube, bladder, and skin. To achieve this, a wireless non-invasive sensor system provided by greenTEG AG, Switzerland, was affixed to different body locations (clavicular and lateral chest) of each catheterized patient (equipped with a temperature probe) admitted to the intensive care unit. Furthermore, tympanic temperatures were recorded at specified intervals. The measurement duration ranged from a minimum of six hours to a maximum of six days, resulting in the analysis of a total of 355 simultaneous temperature measurements.In this study, a wearable temperature measurement system attached to two different body sites revealed a consistent negative bias compared to bladder temperature. In addition, the measurements were particularly influenced by body constitution. The tested system in all patients showed a mean absolute error (MAE) of 0.45 °C for the lateral chest and 0.50 °C for the clavicular position. Tympanic measurements had a mean absolute error of 0.35 °C. In patients with body mass index (BMI) ≥ 25 the MAE increased to 0.5 °C for the lateral chest and 0.56 °C for the clavicular position. In contrast, the tympanic measurement had a reduced MAE of 0.32 °C, which is well below this threshold when compared to bladder measurements.In conclusion the investigated system did not meet the clinically relevant acceptance criteria and showed low precision in correctly identifying fever episodes compared to invasive temperature probes, however its main advantage lies in its continuity and non-invasiveness. This makes it a potential alternative to intermittent tympanic measurement devices. In this study we were able to show, that in at least one subset of patients, the non-invasive and continuous device demonstrated a precision comparable to tympanic measurements.The accuracy of all non-invasive methods was lower than in previous studies, suggesting that the use of bladder temperature as reference and user related variations may have introduced additional errors.

Indexed as

Body TemperatureIntensive Care UnitsUrinary BladderAdultAgedAged, 80 and overCritical CareEquipment DesignFemaleHumansMaleMiddle AgedMonitoring, PhysiologicReproducibility of ResultsSkin TemperatureThermometers

Identifiers

PMID39066870
PMCPMC11821743

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.