Evidence map›Paper›PMID 39066685›Full record

ArticleOtology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology2024

Auditory Localization Performance in Cochlear Implant Recipients With Single-Sided Deafness: The Challenges and Limitations of Current Outcome Metrics.

Chioma Anidi, Obada Abdulrazzak, Gerilyn Jones, Madison V Epperson, Nadine I Ibrahim, Renee M Banakis Hartl

Abstract read
In one paragraph

Article in Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Comparing Bilateral and Single-Sided Deaf Cochlear Implant Recipients in a Novel Speech-in-Noise and Localization Task.Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Chioma AnidiUniversity of Michigan Medical School, Ann Arbor, Michigan.
Obada AbdulrazzakDepartment of Otolaryngology-Head and Neck Surgery, University of Michigan, Ann Arbor, Michigan.
Gerilyn JonesDepartment of Otolaryngology-Head and Neck Surgery, University of Michigan, Ann Arbor, Michigan.
Madison V EppersonDepartment of Otolaryngology-Head and Neck Surgery, University of Michigan, Ann Arbor, Michigan.
Nadine I IbrahimDepartment of Otolaryngology-Head and Neck Surgery, University of Michigan, Ann Arbor, Michigan.
Renee M Banakis HartlDepartment of Otolaryngology-Head and Neck Surgery, University of Michigan, Ann Arbor, Michigan.ORCID 0000-0002-6254-1908

Funding

Sensory Mechanisms and Disorders - Administrative SupplementT32DC000011 · NIDCD · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI Michael Thomas Roberts · 1989 to 2026
$9.5M
Michigan Otolaryngology Research Education (MORE)R25DC020262 · NIDCD · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI Gabriel Corfas · 2023 to 2026
$1.1M
NIDCD NIH HHS R25 DC020262NIDCD NIH HHS T32 DC000011
6 · The paper itself

Abstract

hypothesisAcoustic localization accuracy metrics currently employed in clinical literature both overestimate and underestimate performance benefit of cochlear implantation (CI) for single-sided deafness (SSD).

backgroundAlthough localization in SSD with CI has been investigated, performance characterization has relied heavily on average error. Although attractively concise, this measure may misrepresent performance. Here, we characterize frequency-specific localization on a granular level in subjects with CI for SSD as a critical analysis of localization outcome metrics.

methodsEight CI recipients with SSD were recruited. Stimuli of broadband (BBN) and narrowband noise (NBN) at low (500 Hz), mid (1000 Hz), and high (4000 Hz) frequencies were presented in a semianechoic chamber. Localization accuracy was quantified in mean angular error (MAE) and linear regression slope.

resultsUse of a CI for SSD subjects improved localization performance by slope for all stimuli ( p ≤ 0.0033) to a level that was equal to normal-hearing controls at 1 and 4 kHz ( p ≥ 0.2281). MAE was also significantly improved for SSD subjects using CI for BBN stimuli ( p ≪ 0.0001); however, no statistically significant improvement in MAE was seen for NBN ( p ≥ 0.5773) with CI use. Descriptive analysis of individual subject performance highlights the reasons for contradictory results.

conclusionThere is inherent challenge in characterizing localization benefit for individuals with CI for SSD. Our data demonstrate the limitations of utilization of average error as the sole metric for outcome benefit. We emphasize the importance of continued research investigating alternative outcome measures as we work toward a more refined understanding of the potential benefits and limitations of cochlear implantation for SSD.

Indexed as

Cochlear ImplantationCochlear ImplantsHearing Loss, UnilateralSound LocalizationAcoustic StimulationAdultAgedFemaleHumansMaleMiddle AgedTreatment Outcome

Identifiers

PMID39066685
PMCPMC12326569

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.