Day-to-Day Variability in Measurements of Respiration Using Bioimpedance from a Non-Standard Location.

Krittika Goyal, Dishant Shah, Steven W Day

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Krittika GoyalDepartment of Manufacturing and Mechanical Engineering Technology, Rochester Institute of Technology, Rochester, NY 14623, USA.
Dishant ShahDepartment of Manufacturing and Mechanical Engineering Technology, Rochester Institute of Technology, Rochester, NY 14623, USA.
Steven W DayDepartment of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY 14623, USA.ORCID 0000-0002-7211-6745

Funding

Inconspicuous Daily Monitoring to Reduce Heart Failure HospitalizationsR01NR018301 · NINR · ROCHESTER INSTITUTE OF TECHNOLOGY · PI WANG, LINWEI, ZAREBA, WOJCIECH · 2020 to 2024
$2.8M
NINR NIH HHS R01 NR018301SD supported by Harvey J Palmer Professorship from KGCOE and KG by start-up from CET, both at RIT. n/a
6 · The paper itself

Abstract

Non-invasive monitoring of pulmonary health may be useful for tracking several conditions such as COVID-19 recovery and the progression of pulmonary edema. Some proposed methods use impedance-based technologies to non-invasively measure the thorax impedance as a function of respiration but face challenges that limit the feasibility, accuracy, and practicality of tracking daily changes. In our prior work, we demonstrated a novel approach to monitor respiration by measuring changes in impedance from the back of the thigh. We reported the concept of using thigh-thigh bioimpedance measurements for measuring the respiration rate and demonstrated a linear relationship between the thigh-thigh bioimpedance and lung tidal volume. Here, we investigate the variability in thigh-thigh impedance measurements to further understand the feasibility of the technique for detecting a change in the respiratory status due to disease onset or recovery if used for long-term in-home monitoring. Multiple within-session and day-to-day impedance measurements were collected at 80 kHz using dry electrodes (thigh) and wet electrodes (thorax) across the five healthy subjects, along with simultaneous gold standard spirometer measurements for three consecutive days. The peak-peak bioimpedance measurements were found to be highly correlated (0.94 ± 0.03 for dry electrodes across thigh; 0.92 ± 0.07 for wet electrodes across thorax) with the peak-peak spirometer tidal volume. The data across five subjects indicate that the day-to-day variability in the relationship between impedance and volume for thigh-thigh measurements is smaller (average of 14%) than for the thorax (40%). However, it is affected by food and water and might limit the accuracy of the respiratory tidal volume.

Indexed as

COVID-19Electric ImpedanceAdultElectrodesFemaleHumansMaleMonitoring, PhysiologicRespirationSARS-CoV-2ThighTidal Volumebioimpedance-based sensingdry electrodeshome care follow-uprespiration monitoringwearable sensors

Identifiers

PMID39066010
PMCPMC11280867

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.