Evidence map›Paper›PMID 39065961›Full record

ArticleSensors (Basel, Switzerland)2024

Measurement Error Analysis of Seawater Refractive Index: A Measurement Sensor Based on a Position-Sensitive Detector.

Guanlong Zhou, Liyan Li, Yan Zhou, Xinyu Chen

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Guanlong ZhouSchool of Physics, Changchun University of Science and Technology, Changchun 130022, China.
Liyan LiOptoelectronics System Laboratory, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China.ORCID 0000-0003-4295-4614
Yan ZhouOptoelectronics System Laboratory, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China.
Xinyu ChenSchool of Physics, Changchun University of Science and Technology, Changchun 130022, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The seawater refractive index is an essential parameter in ocean observation, making its high-precision measurement necessary. This can be effectively achieved using a position-sensitive detector-based measurement system. However, in the actual measurement process, the impact of the jitter signal measurement error on the results cannot be ignored. In this study, we theoretically analysed the causes of long jitter signals during seawater refractive index measurements and quantified the influencing factors. Through this analysis, it can be seen that the angle between the two windows in the seawater refractive index measurement area caused a large error in the results, which could be effectively reduced by controlling the angle to within 2.06°. At the same time, the factors affecting the position-sensitive detector's measurement accuracy were analysed, with changes to the background light, the photosensitive surface's size, and the working environment's temperature leading to its reduction. To address the above factors, we first added a 0.9 nm bandwidth, narrow-band filter in front of the detector's photosensitive surface during system construction to filter out any light other than that from the signal light source. To ensure the seawater refractive index's measuring range, a position-sensitive detector with a photosensitive surface size of 4 mm × 4 mm was selected; whereas, to reduce the working environment's temperature variation, we partitioned the measurement system. To validate the testing error range of the optimised test system, standard seawater samples were measured under the same conditions, showing a reduction in the measurement system's jitter signal from 0.0022 mm to 0.0011 mm, before and after optimisation, respectively, as well as a reduction in the refractive index's deviation. The experimental results show that the refractive index of seawater was effectively reduced by adjusting the measurement system's optical path and structure.

Indexed as

error analysisoptical measurementposition-sensitive detectorrefractive index measurement sensor

Identifiers

PMID39065961
PMCPMC11280974

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.