ArticleSensors (Basel, Switzerland)2024
On the Performance of a Horizontally Mounted ADCP in an Energetic Tidal Environment for Floating Tidal Turbine Applications.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
Incident flow measurement is key in the tidal industry for conducting power performance assessments. This paper explores the use of a horizontally mounted Nortek Signature 500 Acoustic Doppler Current Profiler (ADCP) as a means for incident flow measurement onboard a utility-scale tidal turbine. This study shows that the measurement range of an ADCP mounted horizontally in highly dynamic tidal flow (up to 4 m/s) is less than the maximum range stated by the manufacturer. The ability for the horizontal ADCP to accurately resolve velocities in a multi-beam configuration is also analysed. Effects from both vertical shear and beam selection result in incident flow velocities that differ from a single horizontal beam recording. The maximum measurement range of the instrument is found to depend on current speed and on the proportion of data loss that is acceptable to the user. The ability of the ADCP to record data from the free-stream velocity two equivalent diameters upstream of the O2, as set out by IEC TS 62600-200, is considered. It is found that at this distance, there is 90% data loss. Accepting only 10% data loss across all flow speeds resulted in a maximum range of 31 m for a Nortek Signature 500 in this study. While some limitations of an ADCP deployed horizontally in highly energetic tidal flow are identified, the benefits of mounting the sensor close to the rotor facing horizontally into the incoming flow mean that valuable data are still produced for tidal turbine operators.