Evidence map›Paper›PMID 39064445›Full record

ArticleMicromachines2024

Impact of Impeller Speed Adjustment Interval on Hemolysis Performance of an Intravascular Micro-Axial Blood Pump.

Yuan Liu, Yuanfei Zhu, Shangting Wang, Hualin Fu, Zhexin Lu, Ming Yang

Abstract read
In one paragraph

Article in Micromachines, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. PreliminaryFrontiers in medical technology · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yuan LiuDepartment of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
Yuanfei ZhuDepartment of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.ORCID 0000-0002-7578-3965
Shangting WangDepartment of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
Hualin FuDepartment of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
Zhexin LuDepartment of Cardiovascular Surgery, Shanghai General Hospital, Shanghai 201620, China.
Ming YangDepartment of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.

Funding

National Key R&D Program of China 2022YFC2402601National Natural Science Foundation of China 32171357
6 · The paper itself

Abstract

backgroundIn recent years, intravascular micro-axial blood pumps have been increasingly used in the treatment of patients with cardiogenic shock. The flow rate of such blood pumps requires adjustment based on the patient's physiological condition. Compared to a stable flow state with fixed rotation speed, adjusting the speed of blood pump impeller to alter flow rate may lead to additional hemolysis. This study aimed at elucidating the relationship between adjusting interval of a blood pump's impeller speed and the hemolysis index.

methodsBy comparing simulation results with P-Q characteristic curves of the blood pump measured by experiments, the accuracy of the blood pump flow field simulation model was confirmed. In this study, a drainage tube was employed as the device analogous to an intravascular micro-axial blood pump for achieving similar shear stress levels and residence times. The hemolysis finite element prediction method based on a power-law model was validated through hemolysis testing of porcine blood flow through the drainage tube. The validated models were subsequently utilized to investigate the impact of impeller speed adjusting intervals on hemolysis in the blood pump.

resultsCompared to steady flow, the results demonstrate that the hemolysis index increased to 6.3% when changing the blood pump flow rate from 2 L/min to 2.5 L/min by adjusting the impeller speed within 0.072 s.

conclusionsAn adjustment time of impeller speed longer than 0.072 s can avoid extra hemolysis when adjusting the intravascular micro-axial blood pump flow rate from 2 L/min to 2.5 L/min.

Indexed as

finite element simulationflow rate adjustmenthemolysis estimationintravascular micro-axial blood pumpshear stress

Identifiers

PMID39064445
PMCPMC11278578

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.