Evidence map›Paper›PMID 39063706›Full record

ArticleMaterials (Basel, Switzerland)2024

An Ultra-Wideband Frequency Selective Rasorber with Low Infrared Emissivity.

Hang Song, Yuning Zhang, Shengjun Zhang, Jingfeng Li, Xia Ai, Han Zhang, Jiaqi Liu

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Hang SongNational Key Laboratory of Science & Technology on Test Physics and Numerical Mathematics, Beijing 100071, China.ORCID 0000-0002-8544-3649
Yuning ZhangNational Key Laboratory of Science & Technology on Test Physics and Numerical Mathematics, Beijing 100071, China.
Shengjun ZhangNational Key Laboratory of Science & Technology on Test Physics and Numerical Mathematics, Beijing 100071, China.
Jingfeng LiNational Key Laboratory of Science & Technology on Test Physics and Numerical Mathematics, Beijing 100071, China.
Xia AiNational Key Laboratory of Science & Technology on Test Physics and Numerical Mathematics, Beijing 100071, China.
Han ZhangNational Key Laboratory of Science & Technology on Test Physics and Numerical Mathematics, Beijing 100071, China.
Jiaqi LiuNational Key Laboratory of Science & Technology on Test Physics and Numerical Mathematics, Beijing 100071, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The paper proposes an ultra-wideband frequency selective rasorber (FSR) with low infrared emissivity for the composite detection threat of both radars and infrared sensors. Firstly, the equivalent circuit (EC) method based on transmission line (TL) theory is utilized to analyze the absorption/transmission conditions. Then, based on the analysis above, sinusoidal microstrip lines with non-frequency-varying characteristics are adopted in the design, which significantly enhances the transmission bandwidth of FSR. The FSR demonstrates an absorption band ranging from 2.65 GHz to 8.80 GHz and a transmission band ranging from 9.15 GHz to 17.71 GHz. Furthermore, an infrared shielding layer (IRSL) exhibiting low emissivity in the infrared band and high transmittance in the microwave band is applied to the FSR. The simulation and experiment results verify that the IRSL-FSR demonstrates an ultra-wide transmission band ranging from 9.16 GHz to 17.94 GHz and an ultra-wide absorption band ranging from 2.66 GHz to 8.01 GHz. Additionally, it exhibits a low emissivity value (0.23) in 8-14 μm, providing a viable solution to the formidable challenge of radar-infrared bistealth for satellites and other communication-enabled flying platforms.

Indexed as

frequency selective rasorber (FSR)infrared shielding layer (IRSL)low infrared emissivitysinusoidal microstrip linesultra-wideband

Identifiers

PMID39063706
PMCPMC11278342

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.