ArticleBioengineering (Basel, Switzerland)2024
Effect of Sextant Fixating Angle of Spiral Clavicle Plate on Biomechanical Stability-A Preliminary Finite Element Study.
Article in Bioengineering (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionA spiral clavicle plate has been accepted for its superior multidirectional compatibility in the treatment of midshaft clavicle fractures from a biomechanical perspective. However, the influence of the sextant angle (spiral level) definition on biomechanical performance has not been clarified. A conceptual finite element analysis was conducted to identify the advantages and drawbacks of spiral clavicle plates with various sextant angle definitions.
methodsConventional superior and three different conceptual spiral plates with sextant angle definitions ranging from 45 to 135 degrees were constructed to restore an OTA 15-B1.3 midshaft clavicle fracture model. Three major loading scenarios (cantilever downward bending, axial compression, and axial torsion) were simulated to evaluate the reconstructed structural stiffness and the stress on the clavicle plate and bone screws.
resultsThe spiral clavicle plate demonstrated greater capability in resisting cantilever downward bending with an increase in sextant angle and showed comparable structural stiffness and implant stress compared to the superior clavicle plate. However, weakened resistance to axial compression load was noted for the spiral clavicle plate, with lowered stiffness and increased stress on the clavicle plate and screws as the spiral level increased.
conclusionThe spiral clavicle plate has been reported to offer multidirectional compatibility for the treatment of midshaft clavicle fractures, as well as geometric advantages in anatomical matching and reduced skin prominence after surgery. The current study supports that remarkable cantilever bending strength can be achieved with this plate. However, users must consider the potential drawback of lowered axial compression resistance in safety considerations.