ArticleBioengineering (Basel, Switzerland)2024
Assessing the Impact of PRESERFLO MicroShunt on Intraocular Pressure in Porcine Eyes Ex Vivo Using Infusion Pump System.
Article in Bioengineering (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- In Vitro Analysis of Pressure Resistance in the Paul Glaucoma Implant and Ahmed ClearPath 250 With and Without Polypropylene Thread Inside the Tube.Translational vision science & technology · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
To evaluate the effectiveness of the PRESERFLO MicroShunt (PFM) in reducing intraocular pressure (IOP) ex vivo in porcine eyes using an infusion pump system and to simulate various IOP conditions, In this study, porcine eyes received increasing flows between 2 and 20 μL/min. IOP measurements were taken under conditions with and without the PFM [PFM (+) and PFM (-), respectively]. In the PFM (-) group, IOP increased from 7.4 mmHg to 46.3 mmHg as the flow rate increased from 2 μL/min to 20 μL/min. The rate of IOP reduction (%ΔIOP) rose with increasing flow rates, although the absolute IOP values achieved with the PFM insertion also increased. The correlation between IOPs in the PFM (-) conditions and the %ΔIOP was modeled as %ΔIOP = 22.4 Ln [PFM(-) IOP] - 41.7. According to this equation, IOP reduction by PFM insertion is 0% at IOPs of 6.4 mmHg or lower. IOP reductions of 10%, 20%, 30%, and 40% were observed when the pre-insertion IOPs were 10.1, 15.7, 24.6, and 38.4 mmHg, respectively. Achievable post-insertion IOP levels of ≤21 mmHg, ≤18 mmHg, ≤15 mmHg, and ≤12 mmHg corresponded to the initial IOPs of 33 mmHg, 26 mmHg, 20 mmHg, and 14.8 mmHg, respectively. In conclusion, the PFM effectively reduced IOP within a specific range of IOP values in an ex vivo experimental system. In clinical situations, the PFM is unlikely to be effective at low IOP levels. At higher levels, the PFM reduces IOP, but it may be insufficient to achieve the target IOP.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials