Evidence map›Paper›PMID 39060904›Full record

ReviewApplied health economics and health policy2024

Sedaconda ACD-S for Sedation with Volatile Anaesthetics in Intensive Care: A NICE Medical Technologies Guidance.

Michal Pruski, Susan O'Connell, Laura Knight, Rhys Morris

Abstract readReview
PubMed Publisher
In one paragraph

Review in Applied health economics and health policy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Michal PruskiCEDAR, Cardiff and Vale University Health Board, Cardiff, UK. Michal.Pruski@wales.nhs.uk.ORCID 0000-0001-7582-1418
Susan O'ConnellCEDAR, Cardiff and Vale University Health Board, Cardiff, UK.
Laura KnightCEDAR, Cardiff and Vale University Health Board, Cardiff, UK.
Rhys MorrisCEDAR, Cardiff and Vale University Health Board, Cardiff, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Intensive care unit (ICU) patients receive highly complex care and often require sedation as part of their management. ICU sedation has traditionally been delivered using intravenous (IV) agents due to the impractical use of anaesthetic machines in this setting, which are used to deliver volatile sedation. Sedaconda anaesthetic conserving device (ACD)-S (previously known as AnaConDa-S) is a device which allows for the delivery of volatile sedation via the majority of mechanical ventilators by being inserted in the breathing circuit where the heat and moisture exchanger is normally placed. The National Institute of Health and Care Excellence (NICE), as part of the Medical Technologies Evaluation Programme, considered the potential benefits of using Sedaconda ACD-S compared to standard IV sedation in ICU patients. Here we describe the evidence evaluation undertaken by NICE on this technology, supported by CEDAR. CEDAR considered the evidence present in 21 publications that compared the clinical outcomes of patients receiving Sedaconda ACD-S-delivered sedation and IV sedation, and critiqued the economic model provided by the manufacturer. Clinical expert input during the evaluation process was used extensively to ensure that the relevant clinical evidence was captured and that the economic model was suitable for the UK setting. Due to the uncertainty of the evidence, sensitivity analysis was carried out on the key economic inputs to ensure the reliability of the results. Economic modelling has shown that Sedaconda ACD-S-delivered isoflurane sedation is cost saving on a 30-day horizon compared to IV sedation by £3833.76 per adult patient and by £2837.41 per paediatric patient. Clinical evidence indicated that Sedaconda ACD-S-delivered isoflurane sedation is associated with faster patient wake-up times than standard of care. Consequently, NICE recommended Sedaconda ACD-S as an option for delivering sedation in the ICU setting, but noted that further research should inform whether Sedaconda ACD-S-delivered sedation is of benefit to any particular subgroup of patients.

Indexed as

Critical CareAnesthetics, InhalationCost-Benefit AnalysisHumansIntensive Care UnitsProcedural SedationTechnology Assessment, BiomedicalUnited KingdomAnesthetics, Inhalation

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.