Evidence map›Paper›PMID 39058061›Full record

ArticleTomography (Ann Arbor, Mich.)2024

A Novel and Reliable Pixel Response Correction Method (DAC-Shifting) for Spectral Photon-Counting CT Imaging.

Navrit Johan Singh Bal, Imaiyan Chitra Ragupathy, Trine Tramm, Jasper Nijkamp

Abstract read
In one paragraph

Article in Tomography (Ann Arbor, Mich.), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Navrit Johan Singh BalDepartment of Clinical Medicine, Aarhus University, 8200 Aarhus, Denmark.ORCID 0000-0002-8294-1175
Imaiyan Chitra RagupathyDepartment of Clinical Medicine, Aarhus University, 8200 Aarhus, Denmark.ORCID 0009-0007-5853-8523
Trine TrammDepartment of Clinical Medicine, Aarhus University, 8200 Aarhus, Denmark.ORCID 0000-0003-3894-4552
Jasper NijkampDepartment of Clinical Medicine, Aarhus University, 8200 Aarhus, Denmark.ORCID 0000-0001-7523-5881

Funding

Aarhus University Research Foundation AUFF-E-2021-9-15Danish Cancer Society R279-A16481Novo Nordisk Foundation NNF195A0059372
6 · The paper itself

Abstract

Spectral photon-counting cone-beam computed tomography (CT) imaging is challenged by individual pixel response behaviours, which lead to noisy projection images and subsequent image artefacts like rings. Existing methods to correct for this either use calibration measurements, like signal-to-thickness calibration (STC), or perform a post-processing ring artefact correction of sinogram data or scan reconstructions without taking the pixel response explicitly into account. Here, we present a novel post-processing method (digital-to-analogue converter (DAC)-shifting) which explicitly measures the current pixel response using flat-field images and subsequently corrects the projection data. The DAC-shifting method was evaluated using a repeat series of the spectral photon-counting imaging (Medipix3) of a phantom with different density inserts and iodine K-edge imaging. The method was also compared against polymethyl methacrylate (PMMA)-based STC. The DAC-shifting method was shown to be effective in correcting individual pixel responses and was robust against detector instability; it led to a 47.4% average reduction in CT-number variation in homogeneous materials, with a range of 40.7-55.6%. On the contrary, the STC correction showed varying results; a 13.7% average reduction in CT-number variation, ranging from a 43.7% increase to a 45.5% reduction. In K-edge imaging, DAC-shifting provides a sharper attenuation peak and more uniform CT values, which are expected to benefit iodine concentration quantifications.

Indexed as

ArtifactsPhantoms, ImagingPhotonsAlgorithmsCalibrationCone-Beam Computed TomographyHumansImage Processing, Computer-AssistedPolymethyl MethacrylateReproducibility of ResultsTomography, X-Ray ComputedPolymethyl Methacrylatecone-beam computed tomographyK-edge imagingMedipix3photon-counting detectorpixel response correctionspectral computed tomography

Identifiers

PMID39058061
PMCPMC11281142

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.