Evidence map›Paper›PMID 39056599›Full record

ArticleBiosensors2024

A Scalable, Programmable Neural Stimulator for Enhancing Generalizability in Neural Interface Applications.

Meng Yin, Xiao Wang, Liuxindai Zhang, Guijun Shu, Zhen Wang, Shoushuang Huang, Ming Yin

Abstract read
In one paragraph

Article in Biosensors, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Meng YinState Key Laboratory of Digital Medical Engineering, School of Biomedical Engineering, Hainan University, Haikou 570228, China.ORCID 0009-0008-4878-9991
Xiao WangState Key Laboratory of Digital Medical Engineering, School of Biomedical Engineering, Hainan University, Haikou 570228, China.ORCID 0000-0001-5546-5647
Liuxindai ZhangState Key Laboratory of Digital Medical Engineering, School of Biomedical Engineering, Hainan University, Haikou 570228, China.
Guijun ShuState Key Laboratory of Digital Medical Engineering, School of Biomedical Engineering, Hainan University, Haikou 570228, China.
Zhen WangState Key Laboratory of Digital Medical Engineering, School of Biomedical Engineering, Hainan University, Haikou 570228, China.
Shoushuang HuangState Key Laboratory of Digital Medical Engineering, School of Biomedical Engineering, Hainan University, Haikou 570228, China.
Ming YinState Key Laboratory of Digital Medical Engineering, School of Biomedical Engineering, Hainan University, Haikou 570228, China.

Funding

the Key R&D Project of Hainan Province ZDYF2021SHFZ083the Major Science and Technology Projects of Hainan Province ZDKJ2021032the National Natural Science Foundation of China 32160204the Science and Technology Innovation 2030-Major Project 2022ZD0208602
6 · The paper itself

Abstract

Each application of neurostimulators requires unique stimulation parameter specifications to achieve effective stimulation. Balancing the current magnitude with stimulation resolution, waveform, size, and channel count is challenging, leading to a loss of generalizability across broad neural interfaces. To address this, this paper proposes a highly scalable, programmable neurostimulator with a System-on-Chip (SOC) capable of 32 channels of independent stimulation. The compliance voltage reaches up to ±22.5 V. A pair of 8-bit current-mode DACs support independent waveforms for source and sink operations and feature a user-selectable dual range for low-current intraparenchymal microstimulation with a resolution of 4.31 μA/bit, as well as high current stimulation for spinal cord and DBS applications with a resolution of 48.00 μA/bit, achieving a wide stimulation range of 12.24 mA while maintaining high-resolution biological stimulation. A dedicated communication protocol enables full programmable control of stimulation waveforms, effectively improving the range of stimulation parameters. In vivo electrophysiological experiments successfully validate the functionality of the proposed stimulator. This flexible stimulator architecture aims to enhance its generality across a wide range of neural interfaces and will provide more diverse and refined stimulation strategies.

Indexed as

Spinal CordAnimalsElectric StimulationHumanscompliance voltageneural interfaceneurostimulatorSoCstimulation resolution

Identifiers

PMID39056599
PMCPMC11275035

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390