Evidence map›Paper›PMID 39056596›Full record

ArticleBiosensors2024

MeNPs-PEDOT Composite-Based Detection Platforms for Epinephrine and Quercetin.

Sorina Alexandra Leau, Mariana Marin, Ana Maria Toader, Mihai Anastasescu, Cristian Matei, Cecilia Lete, Stelian Lupu

Abstract read
In one paragraph

Article in Biosensors, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sorina Alexandra LeauDepartment of Electrochemistry and Corrosion, Institute of Physical Chemistry-Ilie Murgulescu of the Romanian Academy, 202 Splaiul Independentei, 060021 Bucharest, Romania.ORCID 0000-0003-2754-3550
Mariana MarinDepartment of Electrochemistry and Corrosion, Institute of Physical Chemistry-Ilie Murgulescu of the Romanian Academy, 202 Splaiul Independentei, 060021 Bucharest, Romania.ORCID 0000-0001-9898-0796
Ana Maria ToaderDepartment of Electrochemistry and Corrosion, Institute of Physical Chemistry-Ilie Murgulescu of the Romanian Academy, 202 Splaiul Independentei, 060021 Bucharest, Romania.ORCID 0000-0002-5061-2617
Mihai AnastasescuDepartment of Electrochemistry and Corrosion, Institute of Physical Chemistry-Ilie Murgulescu of the Romanian Academy, 202 Splaiul Independentei, 060021 Bucharest, Romania.ORCID 0000-0002-4865-2652
Cristian MateiDepartment of Inorganic Chemistry, Physical Chemistry and Electrochemistry, Faculty of Chemical Engineering and Biotechnologies, National University of Science and Technology Politehnica of Bucharest, 1-7 Polizu Gheorghe, 011061 Bucharest, Romania.ORCID 0000-0001-9830-8246
Cecilia LeteDepartment of Electrochemistry and Corrosion, Institute of Physical Chemistry-Ilie Murgulescu of the Romanian Academy, 202 Splaiul Independentei, 060021 Bucharest, Romania.
Stelian LupuDepartment of Analytical Chemistry and Environmental Engineering, Faculty of Chemical Engineering and Biotechnologies, National University of Science and Technology Politehnica of Bucharest, 1-7 Polizu Gheorghe, 011061 Bucharest, Romania.

Funding

Ministry of Research, Innovation and Digitization PN-III-P2-2.1-PED-2021-3693
6 · The paper itself

Abstract

The development of low-cost, sensitive, and simple analytical tools for biomolecule detection in health status monitoring is nowadays a growing research topic. Sensing platforms integrating nanocomposite materials as recognition elements in the monitoring of various biomolecules and biomarkers are addressing this challenging objective. Herein, we have developed electrochemical sensing platforms by means of a novel fabrication procedure for biomolecule detection. The platforms are based on commercially available low-cost conductive substrates like glassy carbon and/or screen-printed carbon electrodes selectively functionalized with nanocomposite materials composed of Ag and Au metallic nanoparticles and an organic polymer, poly(3,4-ethylenedioxythiophene). The novel fabrication method made use of alternating currents with controlled amplitude and frequency. The frequency of the applied alternating current was 100 mHz for the polymer deposition, while a frequency value of 50 mHz was used for the in situ electrodeposition of Ag and Au nanoparticles. The selected frequency values ensured the successful preparation of the composite materials. The use of readily available composite materials is intended to produce cost-effective analytical tools. The judicious modification of the organic conductive matrix by various metallic nanoparticles, such as Ag and Au, extends the potential applications of the sensing platform toward a range of biomolecules like quercetin and epinephrine, chosen as benchmark analytes for proof-of-concept antioxidant and neurotransmitter detection. The sensing platforms were tested successfully for quercetin and epinephrine determination on synthetic and real samples. Wide linear response ranges and low limit-of-detection values were obtained for epinephrine and quercetin detection.

Indexed as

Biosensing TechniquesBridged Bicyclo Compounds, HeterocyclicElectrochemical TechniquesEpinephrineGoldMetal NanoparticlesNanocompositesPolymersQuercetinElectrodesHumansSilverBridged Bicyclo Compounds, HeterocyclicEpinephrineGoldpoly(3,4-ethylene dioxythiophene)PolymersQuercetinSilveralternating currentsepinephrinenanocomposite materialsquercetinsensing platform

Identifiers

PMID39056596
PMCPMC11274438

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.