Evidence map›Paper›PMID 39055412›Full record

ArticleCureus2024

Sparing the Hippocampus in Prophylactic Cranial Irradiation Using Three Different Linear Accelerators: A Comparative Study.

Georgios Giakoumettis, Areti Gkantaifi, Dimitrios Giakoumettis, Emmanouil Papanastasiou, Georgios Plataniotis, Despoina Misailidou, Konstantinos Kouskouras, Panagiotis D Bamidis, Anastasios Siountas

Abstract read
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Georgios GiakoumettisMedical Physics and Digital Innovation Laboratory, AHEPA University Hospital, Aristotle University of Thessaloniki, Thessaloniki, GRC.
Areti GkantaifiRadiation Oncology, AHEPA University Hospital, Aristotle University of Thessaloniki, Thessaloniki, GRC.
Dimitrios GiakoumettisNeurosurgery, Agios Savvas, General Anticancer-Oncological Hospital of Athens, Athens, GRC.
Emmanouil PapanastasiouMedical Physics and Digital Innovation Laboratory, AHEPA University Hospital, Aristotle University of Thessaloniki, Thessaloniki, GRC.
Georgios PlataniotisRadiation Oncology, AHEPA University Hospital, Aristotle University of Thessaloniki, Thessaloniki, GRC.
Despoina MisailidouRadiation Oncology, Interbalkan European Medical Center of Thessaloniki, Thessaloniki, GRC.
Konstantinos KouskourasRadiology, AHEPA University Hospital, Aristotle University of Thessaloniki, Thessaloniki, GRC.
Panagiotis D BamidisMedicine, Aristotle University of Thessaloniki, Thessaloniki, GRC.
Anastasios SiountasMedical Physics and Digital Innovation Laboratory, AHEPA University Hospital, Aristotle University of Thessaloniki, Thessaloniki, GRC.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Hippocampus protection, as an organ at risk in brain radiotherapy, might protect patients' quality of life. Prophylactic cranial irradiation (PCI) has been used traditionally in small cell lung cancer (SCLC) patients as it increases survival. This study aimed to discover the contributing parameters for a successful PCI with simultaneous protection of the hippocampus by using three different treatment machines. For this purpose, treatment plans were generated for 45 SCLC patients using three half-arcs in three linear accelerators (LINACs; Elekta Infinity, Synergy, and Axesse; Elekta Ltd, Stockholm, Sweden) with different radiation field sizes and multileaf collimator (MLC) leaf thickness characteristics. The prescribed dose was 25 Gy in 10 fractions. Thresholds for the hippocampus were calculated based on the Radiation Therapy Oncology Group 0933 dose constraints. The planning and treatment system templates were common to all three LINACs. Plan evaluation was based on the dosimetric target coverage by the 95% isodose, the maximum dose of the plan, the conformity index (CI), the degree of plan modulation (MOD), and the patient-specific quality assurance (QA) pass rate. The mean target coverage was highest for Infinity (97.3%), followed by Axesse (96.6%) and Synergy (95.5%). The mean maximum dose was higher for Synergy (27.5 Gy), followed by Infinity (27.0 Gy) and Axesse (26.9 Gy). Axesse plans had the highest CI (0.93), followed by Infinity (0.91) and Synergy (0.88). Plan MOD was lower for Synergy (2.88) compared with Infinity (3.07) and Axesse (3.69). Finally, patient-specific QA was successful in all Infinity plans, in all but one Synergy plan, and in 17/45 Axesse plans, as was expected from the field size in that treatment unit. Based on overall performance, the most favorable combination of target coverage, hippocampus sparing, and plan deliverability was obtained with the LINAC, which has the largest field opening and thinnest MLC leaves.

Indexed as

gamma pass ratehippocampus sparinglinear acceleratorprophylactic cranial irradiation (pci)volumetric‐modulated arc therapy (vmat)

Identifiers

PMID39055412
PMCPMC11272133

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.