Evaluation of superficial xenograft volume estimation by ultrasound and caliper against MRI in a longitudinal pre-clinical radiotherapeutic setting.

Daniel Roth, Marcella Safi, Oskar Vilhelmsson Timmermand, Evangelia Sereti, Malwina Molendowska, Michael Gottschalk, Anders Bjartell, Crister Ceberg, Filip Szczepankiewicz, Joanna Strand

Abstract read
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Daniel RothMedical Radiation Physics, Lund, Lund University, Lund, Sweden.ORCID 0000-0002-4128-0032
Marcella SafiDepartment of Clinical Sciences Lund, Oncology, Lund University, Lund, Sweden.
Oskar Vilhelmsson TimmermandDepartment of Clinical Sciences Lund, Oncology, Lund University, Lund, Sweden.
Evangelia SeretiDept of Translational Medicine, Medical Faculty, Lund University, Lund, Sweden.ORCID 0000-0002-5947-9971
Malwina MolendowskaMedical Radiation Physics, Lund, Lund University, Lund, Sweden.ORCID 0000-0001-8540-8424
Michael GottschalkLund University Bioimaging Centre, Faculty of Medicine, Lund University, Lund, Sweden.
Anders BjartellDept of Translational Medicine, Medical Faculty, Lund University, Lund, Sweden.
Crister CebergMedical Radiation Physics, Lund, Lund University, Lund, Sweden.
Filip SzczepankiewiczMedical Radiation Physics, Lund, Lund University, Lund, Sweden.ORCID 0000-0002-5251-587X
Joanna StrandDepartment of Clinical Sciences Lund, Oncology, Lund University, Lund, Sweden.ORCID 0009-0004-0616-3668

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAccurate tumor volume estimation is important for evaluating the response to radionuclide therapy and external beam radiotherapy as well as to other pharmaceuticals. A common method for monitoring the growth of subcutaneous tumors in pre-clinical models and assessing the treatment response is to measure the tumor length and width by external calipers to estimate its volume. This procedure relies on an assumption of a spheroidal tumor shape wherein the tumor depth equals the width and can yield considerably inaccuracies. Ultrasound imaging is a non-invasive technique that can measure all three axes of the tumor and might be an alternative to caliper measurement with potentially greater accuracy and comparable ease-of-use and throughput. Both 2D and 3D ultrasound imaging are possible, the former offering short scan times without the need for anesthesia and heating-valuable factors for longitudinal studies in large animal cohorts. Nevertheless, tumor volume estimation accuracy by 2D ultrasound imaging has seen limited investigation. In this study we have evaluated the accuracy of tumor volume estimation by caliper and 2D ultrasound with comparisons to reference measurements by magnetic resonance imaging (MRI) in a pre-clinical model of prostate cancer treated with either external beam radiotherapy, radionuclide therapy, or no treatment.

resultsTumor volumes were measured longitudinally in 29 mice by caliper, ultrasound, and MRI before and after external beam radiotherapy, [177Lu]Lu-PSMA-617 radionuclide therapy, or no treatment. Caliper measurements had a marked bias, overestimating the tumor volumes by a median of 150% compared to MRI. Ultrasound measurements were markedly more accurate, with a median bias of -21% compared to MRI.

conclusionUltrasound imaging is a reliable and accurate method for tumor volume estimation in pre-clinical models of radiotherapy, whereas caliper measurements are prone to overestimation.

Indexed as

Magnetic Resonance ImagingProstatic NeoplasmsTumor BurdenUltrasonographyAnimalsCell Line, TumorHumansMaleMiceXenograft Model Antitumor Assays

Identifiers

PMID39052663
PMCPMC11271909

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.