ArticlePloS one2024
Reliability and minimal detectable change of dynamic temporal summation and conditioned pain modulation using a single experimental paradigm.
Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Conditioned Pain Modulation and Pleasant Pain Relief as Complementary Processes Reflecting Individual Differences in Pain Coping: A Clustering Approach.European journal of pain (London, England) · 2026Article
- Article
- Intra- and Inter-examiner Reliability of Quantitative Sensory Testing of Knee Joints in Healthy Subjects.Progress in rehabilitation medicine · 2026Article
- Exploring the Influence of Testosterone on Pain Perception and Modulation Among Men with Low and Normal Testosterone Concentrations.Journal of pain research · 2026Article
- Protolytic properties and biological activity of spinorphin and its butyric acid derivatives in aqueous solution.Amino acids · 2025Article
- A Parallel Human and Rat Investigation of the Interaction Between Descending and Spinal Modulatory Mechanisms.European journal of pain (London, England) · 2025Article
- Translational validity of quantitative sensory testing in chronic pain neuro-sensitization: guide of use and interpretation in osteoarthritis animal models.Frontiers in pain research (Lausanne, Switzerland) · 2025Review
- Ice water immersion does not activate diffuse noxious inhibitory controls of spinal reflexes in sedated or anaesthetised dogs (Frontiers in pain research (Lausanne, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundQuantitative sensory tests (QST) are frequently used to explore alterations in somatosensory systems. Static and dynamic QST like pain threshold and temporal summation (TS) and conditioned pain modulation (CPM) are commonly used to evaluate excitatory and inhibitory mechanisms involved in pain processing. The aim of the present study was to document the reliability and the minimal detectable change (MDC) of these dynamic QST measurements using a standardized experimental paradigm. MATERIAL AND
methodsForty-six (46) pain-free participants took part in 2 identical sessions to collect TS and CPM outcomes. Mechanical (pressure pain threshold [PPT]) and thermal (constant 2-minute heat pain stimulation [HPS]) nociceptive stimuli were applied as test stimuli, before and after a cold-water bath (conditioning stimulus). TS was interpreted as the change in pain perception scores during HPS. CPM were determined by calculating the difference in pain perception between pre- and post- water bath for both PPT and HPS. Relative and absolute reliability were analyzed with intra-class correlation coefficient (ICC2, k), standard error of the measurements (SEMeas) and MDC.
resultsResults revealed a good to excellent relative reliability for static QST (ICC ≥ 0.73). For TS, a poor to moderate relative reliability depending on the calculation methods (ICC = 0.25 ≤ ICC ≤ 0.59), and a poor relative reliability for CPM (ICC = 0.16 ≤ ICC ≤ 0.37), both when measured with mechanical stimulation (PPT) and thermal stimulation (HPS). Absolute reliability varied from 0.73 to 7.74 for static QST, 11 to 22 points for TS and corresponded to 11.42 points and 1.56 points for thermal and mechanical-induced CPM, respectively. MDC analyses revealed that a change of 1.58 to 21.46 point for static QST, 31 to 52 points for TS and 4 to 31 points for CPM is necessary to be interpreted as a real change.
conclusionOur approach seems well-suited to clinical use. Although our method shows equivalent relative and absolute reliability compared to other protocols, we found that the reliability of endogenous pain modulation mechanisms is vulnerable, probably due to its dynamic nature.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials