Evidence map›Paper›PMID 39051274›Full record

ArticleJournal of functional morphology and kinesiology2024

Practical but Inaccurate? A-Mode Ultrasound and Bioelectrical Impedance Underestimate Body Fat Percentage Compared to Dual-Energy X-ray Absorptiometry in Male College Students.

Markus Olinto, Victor César Lins, Gabriel Rocha, Marco Aurélio Dourado, Maurilio Dutra

Abstract read
In one paragraph

Article in Journal of functional morphology and kinesiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Markus OlintoFaculty of Physical Education, University of Brasília, Brasilia 70910-900, Brazil.ORCID 0009-0002-1242-812X
Victor César LinsExercise and Health Research Group, Campus Estrutural, Federal Institute of Education, Science and Technology of Brasilia, Brasilia 71200-020, Brazil.
Gabriel RochaFaculty of Physical Education, University of Brasília, Brasilia 70910-900, Brazil.
Marco Aurélio DouradoExercise and Health Research Group, Campus Estrutural, Federal Institute of Education, Science and Technology of Brasilia, Brasilia 71200-020, Brazil.ORCID 0009-0004-9348-6384
Maurilio DutraFaculty of Physical Education, University of Brasília, Brasilia 70910-900, Brazil.

Funding

Research Support Foundation of the Federal District, Brasília, Brazil 00193.00002363/2022-47
6 · The paper itself

Abstract

Bioelectrical impedance (BIA) and ultrasound (US) have become popular for estimating body fat percentage (BF%) due to their low cost and clinical convenience. However, the agreement of these devices with the gold-standard method still requires investigation. The aim was to analyze the agreement between a gold-standard %BF assessment method with BIA and US devices. Twenty-three men (aged 30.1 ± 7.7 years, weighing 82.5 ± 14.9 kg, 1.77 ± 0.05 m tall) underwent dual-energy X-ray absorptiometry (DXA), BIA (tetrapolar) and US (three-site method) %BF assessments. Pearson and concordance correlations were analyzed. A

Indexed as

bioelectrical impedancebody fatdual-energy X-ray absorptiometryultrasound

Identifiers

PMID39051274
PMCPMC11270340

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.