Evidence map›Paper›PMID 39051045›Full record

ArticleOphthalmology science

Highly Accurate and Precise Automated Cup-to-Disc Ratio Quantification for Glaucoma Screening.

Abadh K Chaurasia, Connor J Greatbatch, Xikun Han, Puya Gharahkhani, David A Mackey, Stuart MacGregor, Jamie E Craig, Alex W Hewitt

Abstract read
In one paragraph

Article in Ophthalmology science. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Effect of disc-fovea angle on glaucoma detection in fundus images.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026
    Observational
  2. Article
  3. Article
  4. Reply.Ophthalmology science
    Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Abadh K ChaurasiaMenzies Institute for Medical Research, University of Tasmania, Hobart, Australia.
Connor J GreatbatchMenzies Institute for Medical Research, University of Tasmania, Hobart, Australia.
Xikun HanQIMR Berghofer Medical Research Institute, Brisbane, Australia.
Puya GharahkhaniQIMR Berghofer Medical Research Institute, Brisbane, Australia.
David A MackeyLions Eye Institute, Centre for Vision Sciences, University of Western Australia, Nedlands, Australia.
Stuart MacGregorQIMR Berghofer Medical Research Institute, Brisbane, Australia.
Jamie E CraigDepartment of Ophthalmology, Flinders University, Flinders Medical Centre, Bedford Park, Australia.
Alex W HewittMenzies Institute for Medical Research, University of Tasmania, Hobart, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: An enlarged cup-to-disc ratio (CDR) is a hallmark of glaucomatous optic neuropathy. Manual assessment of the CDR may be less accurate and more time-consuming than automated methods. Here, we sought to develop and validate a deep learning-based algorithm to automatically determine the CDR from fundus images. Design: Algorithm development for estimating CDR using fundus data from a population-based observational study. Participants: A total of 181 768 fundus images from the United Kingdom Biobank (UKBB), Drishti_GS, and EyePACS. Methods: FastAI and PyTorch libraries were used to train a convolutional neural network-based model on fundus images from the UKBB. Models were constructed to determine image gradability (classification analysis) as well as to estimate CDR (regression analysis). The best-performing model was then validated for use in glaucoma screening using a multiethnic dataset from EyePACS and Drishti_GS. Main Outcome Measures: The area under the receiver operating characteristic curve and coefficient of determination. Results: Our gradability model vgg19_batch normalization (bn) achieved an accuracy of 97.13% on a validation set of 16 045 images, with 99.26% precision and area under the receiver operating characteristic curve of 96.56%. Using regression analysis, our best-performing model (trained on the vgg19_bn architecture) attained a coefficient of determination of 0.8514 (95% confidence interval [CI]: 0.8459-0.8568), while the mean squared error was 0.0050 (95% CI: 0.0048-0.0051) and mean absolute error was 0.0551 (95% CI: 0.0543-0.0559) on a validation set of 12 183 images for determining CDR. The regression point was converted into classification metrics using a tolerance of 0.2 for 20 classes; the classification metrics achieved an accuracy of 99.20%. The EyePACS dataset (98 172 healthy, 3270 glaucoma) was then used to externally validate the model for glaucoma classification, with an accuracy, sensitivity, and specificity of 82.49%, 72.02%, and 82.83%, respectively. Conclusions: Our models were precise in determining image gradability and estimating CDR. Although our artificial intelligence-derived CDR estimates achieve high accuracy, the CDR threshold for glaucoma screening will vary depending on other clinical parameters. Financial Disclosures: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

Indexed as

Computer VisionDeep LearningFundus ImageGlaucomaUK Biobank

Identifiers

PMID39051045
PMCPMC11268341

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.