Evidence map›Paper›PMID 39050910›Full record

ArticleMedical devices (Auckland, N.Z.)2024

Validity of Inertial Measurement Unit (IMU Sensor) for Measurement of Cervical Spine Motion, Compared with Eight Optoelectronic 3D Cameras Under Spinal Immobilization Devices.

Wijittra Liengswangwong, Natcha Lertviboonluk, Chaiyaporn Yuksen, Parunchaya Jamkrajang, Weerawat Limroongreungrat, Atipong Mongkolpichayaruk, Chetsadakon Jenpanitpong, Sorawich Watcharakitpaisan, Chantarat Palee, Picharee Reechaipichitkool and 1 more

Abstract read
In one paragraph

Article in Medical devices (Auckland, N.Z.), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Trial
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Wijittra LiengswangwongDepartment of Emergency Medicine, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
Natcha LertviboonlukDepartment of Emergency Medicine, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.ORCID 0009-0004-9173-0224
Chaiyaporn YuksenDepartment of Emergency Medicine, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.ORCID 0000-0002-4890-7176
Parunchaya JamkrajangCollege of Sports Science and Technology, Mahidol University, Nakhon Pathom, Thailand.
Weerawat LimroongreungratCollege of Sports Science and Technology, Mahidol University, Nakhon Pathom, Thailand.
Atipong MongkolpichayarukCollege of Sports Science and Technology, Mahidol University, Nakhon Pathom, Thailand.
Chetsadakon JenpanitpongDepartment of Emergency Medicine, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.ORCID 0000-0002-2906-7677
Sorawich WatcharakitpaisanDepartment of Emergency Medicine, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.ORCID 0000-0002-5110-1763
Chantarat PaleeDepartment of Emergency Medicine, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.ORCID 0009-0004-3373-6767
Picharee ReechaipichitkoolDepartment of Emergency Medicine, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
Suchada ThaipasongDepartment of Emergency Medicine, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The assessment of cervical spine motion is critical for out-of-hospital patients who suffer traumatic spinal cord injuries, given the profound implications such injuries have on individual well-being and broader public health concerns. 3D Optoelectronic systems (BTS SmartDX) are standard devices for motion measurement, but their price, complexity, and size prevent them from being used outside of designated laboratories. This study was designed to evaluate the accuracy and reliability of an inertial measurement unit (IMU) in gauging cervical spine motion among healthy volunteers, using a 3D optoelectronic motion capture system as a reference. Methods: Twelve healthy volunteers participated in the study. They underwent lifting, transferring, and tilting simulations using a long spinal board, a Sked stretcher, and a vacuum mattress. During these simulations, cervical spine angular movements-including flexion-extension, axial rotation, and lateral flexion-were concurrently measured using the IMU and an optoelectronic device. We employed the Wilcoxon signed-rank test and the Bland-Altman plot to assess reliability and validity. Results: A single statistically significant difference was observed between the two devices in the flexion-extension plane. The mean differences across all angular planes ranged from -1.129° to 1.053°, with the most pronounced difference noted in the lateral flexion plane. Ninety-five percent of the angular motion disparities ascertained by the SmartDX and IMU were less than 7.873° for the lateral flexion plane, 11.143° for the flexion-extension plane, and 25.382° for the axial rotation plane. Conclusion: The IMU device exhibited robust validity when assessing the angular motion of the cervical spine in the axial rotation plane and demonstrated commendable validity in both the lateral flexion and flexion-extension planes.

Indexed as

cervical spine angular motioninertial measurement unitreliabilitySmartDXvalidity

Identifiers

PMID39050910
PMCPMC11268762

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked