Evidence map›Paper›PMID 39050343›Full record

ArticleCureus2024

A Randomized Study Comparing Ultrasound-Guided Internal Jugular Vein Cannulation Using Two Techniques: Short-Axis Out-of-Plane With Dynamic Needle Tip Positioning Versus Long-Axis In-Plane.

Mainak Baidya, Mamta Sinha, Mayank Kumar, Nandkishore Agrawal, Sarita Ramchandani, Gade Sandeep, Swati Vijapurkar

Abstract read
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Mainak BaidyaAnesthesiology, All India Institute of Medical Sciences, Raipur, Raipur, IND.
Mamta SinhaAnesthesiology, All India Institute of Medical Sciences, Raipur, Raipur, IND.
Mayank KumarAnesthesiology, All India Institute of Medical Sciences, Raipur, Raipur, IND.
Nandkishore AgrawalAnesthesiology, Critical Care, and Pain Medicine, All India Institute of Medical Sciences, Raipur, Raipur, IND.
Sarita RamchandaniAnesthesiology, All India Institute of Medical Sciences, Raipur, Raipur, IND.
Gade SandeepCardiac Anesthesia, All India Institute of Medical Sciences, Raipur, Raipur, IND.
Swati VijapurkarAnesthesiology, Critical Care, and Pain Medicine, All India Institute of Medical Sciences, Raipur, Raipur, IND.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction Internal jugular vein (IJV) cannulation is a routine procedure in operating rooms, critical care units, and perioperative settings. Ultrasound guidance has notably increased the success rates of IJV cannulation. A modified ultrasound technique known as the short-axis out-of-plane method with dynamic needle tip positioning (DNTP) allows for continuous visualization of the needle tip throughout the procedure. This study aims to compare the first-pass success rate of IJV cannulation using the DNTP and long-axis in-plane (LAIP) approaches. Methods One hundred patients between 18 and 70 years undergoing elective surgery requiring IJV cannulation were recruited. Patients were assigned randomly to the DNTP group (n = 50) or the LAIP group (n = 50). We recorded the first-pass success rate, time to achieve successful cannulation, number of skin punctures, overall success rate within five minutes, and potential complications such as pneumothorax and hematoma. Results The first pass success rate was higher in the DNTP group (48/50, 96%) as compared to the LAIP group (38/50, 76%, relative risk, 1.67; 95% confidence interval, 0.039-0.707; p = 0.008). The cannulation time was shorter in DNTP (116.98 ± 22.90 seconds) versus the LAIP group (213.04 ± 52.08 seconds; p < 0.001). No complications like pneumothorax or hematoma were noted in both groups. Conclusion We conclude that the ultrasound-guided DNTP technique for IJV cannulation, as compared with the LAIP technique, may significantly improve the first attempt cannulation, number of attempts, and cannulation time.

Indexed as

dynamic needle tip positioningfirst pass successijv cannulationlong axis techniqueshort axis techniqueultrasound-guided

Identifiers

PMID39050343
PMCPMC11267105

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked