Evidence map›Paper›PMID 39048968›Full record

ArticleBMC medical imaging2024

Continuum topological derivative - a novel application tool for denoising CT and MRI medical images.

Viswanath Muthukrishnan, Sandeep Jaipurkar, Nedumaran Damodaran

Abstract read
In one paragraph

Article in BMC medical imaging, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Viswanath MuthukrishnanCentral Instrumentation & Service Laboratory, Guindy Campus, University of Madras, Chennai, India.
Sandeep JaipurkarImage Art, Vijaya Health Centre, Vadapalani, Chennai, India.
Nedumaran DamodaranCentral Instrumentation & Service Laboratory, Guindy Campus, University of Madras, Chennai, India. dnmaran@gmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCT and MRI modalities are important diagnostics tools for exploring the anatomical and tissue properties, respectively of the human beings. Several advancements like HRCT, FLAIR and Propeller have advantages in diagnosing the diseases very accurately, but still have enough space for improvements due to the presence of inherent and instrument noises. In the case of CT and MRI, the quantum mottle and the Gaussian and Rayleigh noises, respectively are still present in their advanced modalities of imaging. This paper addresses the denoising problem with continuum topological derivative technique and proved its trustworthiness based on the comparative study with other traditional filtration methods such as spatial, adaptive, frequency and transformation techniques using measures like visual inspection and performance metrics.

methodsThis research study focuses on identifying a novel method for denoising by testing different filters on HRCT (High-Resolution Computed Tomography) and MR (Magnetic Resonance) images. The images were acquired from the Image Art Radiological Scan Centre using the SOMATOM CT and SIGNA Explorer (operating at 1.5 Tesla) machines. To compare the performance of the proposed CTD (Continuum Topological Derivative) method, various filters were tested on both HRCT and MR images. The filters tested for comparison were Gaussian (2D convolution operator), Wiener (deconvolution operator), Laplacian and Laplacian diagonal (2nd order partial differential operator), Average, Minimum, and Median (ordinary spatial operators), PMAD (Anisotropic diffusion operator), Kuan (statistical operator), Frost (exponential convolution operator), and HAAR Wavelet (time-frequency operator). The purpose of the study was to evaluate the effectiveness of the CTD method in removing noise compared to the other filters. The performance metrics were analyzed to assess the diligence of noise removal achieved by the CTD method. The primary outcome of the study was the removal of quantum mottle noise in HRCT images, while the secondary outcome focused on removing Gaussian (foreground) and Rayleigh (background) noise in MR images. The study aimed to observe the dynamics of noise removal by examining the values of the performance metrics. In summary, this study aimed to assess the denoising ability of various filters in HRCT and MR images, with the CTD method being the proposed approach. The study evaluated the performance of each filter using specific metrics and compared the results to determine the effectiveness of the CTD method in removing noise from the images.

resultsBased on the calculated performance metric values, it has been observed that the CTD method successfully removed quantum mottle noise in HRCT images and Gaussian as well as Rayleigh noise in MRI. This can be evidenced by the PSNR (Peak Signal-to-Noise Ratio) metric, which consistently exhibited values ranging from 50 to 65 for all the tested images. Additionally, the CTD method demonstrated remarkably low residual values, typically on the order of e

conclusionContinuum topological derivative algorithm is found to be constructive in removing prominent noises in both CT and MRI images and can serve as a potential tool for recognition of anatomical details in case of diseased and normal ones. The results obtained from this research work are highly inspiring and offer great promise in obtaining accurate diagnostic information for critical cases such as Thoracic Cavity Carina, Brain SPI Globe Lens 4th Ventricle, Brain-Middle Cerebral Artery, Brain-Middle Cerebral Artery and neoplastic lesions. These findings lay the foundation for implementing the proposed CTD technique in routine clinical diagnosis.

Indexed as

Magnetic Resonance ImagingSignal-To-Noise RatioTomography, X-Ray ComputedAlgorithmsHumansImage Processing, Computer-AssistedContinuum topological derivativeDenoisingGaussian noiseHRCT imagesMRI imagesQuantum mottleRayleigh noise

Identifiers

PMID39048968
PMCPMC11267933

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.