Evidence map›Paper›PMID 39046519›Full record

ArticleGraefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie2024

Optical quality in vitro and in vivo of an extended depth-of-focus intraocular lens with isofocal design.

Sara Fernández-Núñez, Lidia Pérez-Sanz, Jose Antonio Gómez-Pedrero, María García-Montero, César Albarrán-Diego, Nuria Garzón

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Sara Fernández-NúñezDpto. de Óptica, Universidad Complutense de Madrid, Av. Arcos del Jalón 118, Madrid, E-28037, Spain.
Lidia Pérez-SanzDpto.de Optometría y Visión, Universidad Complutense de Madrid, Av. Arcos del Jalón 118, Madrid, E-28037, Spain.
Jose Antonio Gómez-PedreroDpto. de Óptica, Universidad Complutense de Madrid, Av. Arcos del Jalón 118, Madrid, E-28037, Spain.
María García-MonteroDpto.de Optometría y Visión, Universidad Complutense de Madrid, Av. Arcos del Jalón 118, Madrid, E-28037, Spain. mgarc01@ucm.es.
César Albarrán-DiegoDpto. de Óptica y Optometría y Ciencias de la Visión, Universitat de València, Doctor Moliner 50, Burjassot, 46100, Spain.
Nuria GarzónDpto.de Optometría y Visión, Universidad Complutense de Madrid, Av. Arcos del Jalón 118, Madrid, E-28037, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe aim of this study is to compare optical quality results obtained in laboratory analysis (in vitro) versus clinical data (in vivo).

methodsThe optical quality of ISOPure intraocular lens was assessed both in vitro and in vivo using the modulation transfer function (MTF) for 3.0 and 4.5 mm pupil diameters. In vitro measurements were obtained using deflectometer NIMO TRF1504, while in vivo measurements were taken with OPD-Scan III in a set of patients implanted with this lens. Ray tracing techniques were used to determine the MTF and area under MTF curve (MTFa) from the measured wavefront for the isolated lens and for the whole eye.

resultsThe MTF of the isolated lens obtained under both in vitro and in vivo conditions showed comparable results for both pupil sizes. However, differences were found when comparing the MTF of the whole eye with the lens implanted versus the MTF measured in vitro for 4.5 mm pupil size. Also, the MTFa defocus curve was compared with the defocus curve measured in vivo.

conclusionThe defocus curve from the in vivo study aligns closely with the MTFa of the in vitro model, with a useful defocus range of 0.40D. Thus, it is possible to anticipate the visual results of the implanted isofocal lens by using measurements on an optical bench and conducting optical simulations.

Indexed as

Lenses, IntraocularProsthesis DesignRefraction, OcularVisual AcuityAgedDepth PerceptionFemaleHumansMaleMiddle AgedOptics and PhotonicsPupilEDoFIOLOptical benchOptical quality

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.