Evidence map›Paper›PMID 39045406›Full record

ArticleAdvances in radiation oncology2024

Using Scorecards to Tune Ethos Directive Templates: An Adaptive Radiation Therapy Individualized Approach-Cervix Dosimetric Planning Study.

Kareem Rayn, Anthony Magliari, Ryan Clark, Omar Rana, Kevin Moore, Xenia Ray

Abstract read
In one paragraph

Article in Advances in radiation oncology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Kareem RaynDepartment of Radiation Oncology, Columbia University Irving Medical Center, New York, New York.
Anthony MagliariVarian Medical Systems, Inc, Palo Alto, California.
Ryan ClarkVarian Medical Systems, Inc, Palo Alto, California.
Omar RanaBoston University School of Medicine, Boston, Massachusetts.
Kevin MooreDepartment of Radiation Medicine and Applied Sciences, University of California San Diego, San Diego, California.
Xenia RayDepartment of Radiation Medicine and Applied Sciences, University of California San Diego, San Diego, California.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: The Adaptive Radiation Therapy Individualized Approach-Cervix clinical trial uses predefined clinical directive templates (CDTs) combined with RapidPlan dose-volume histogram estimations (DVHe) to guide plan optimization in the Ethos treatment planning system. The dosimetric scorecard is a scoring tool that quantifies improvements in plan quality after physicians have precisely expressed their complete clinical intent. To our knowledge, this is the first study to use the dosimetric scorecard tool to tune an Ethos CDT to improve resulting plan quality. Methods and Materials: Iterative replanning was used to modify the draft CDT (CDT-1) in Ethos 1.1 to generate a new CDT (CDT-2) that maximized the clinical consensus scorecard's total score compared with CDT-1. CDT-2 was established, and resulting plans were compared with and without a DVHe. Additional fixed field intensity modulated radiation therapy beam geometries were compared between CDT-1 and CDT-2, both with DVHe. After obtaining favorable results when comparing CDT-1 versus CDT-2 for 2 test cases, 10 additional cases were retrospectively identified and tested. Results: CDT-2 reduced organ at risk doses without compromising planning target volume coverage in the initial test cases. When combined with DVHe, CDT-2 marginally outperformed CDT-1. Plan quality further improved with a 19-field geometry. In the expanded analysis, CDT-2 achieved higher scores than CDT-1 in most cases, with the 19-field approach showing superiority. Optimization and calculation time increased by 1.9 minutes, monitor unit (MU)/field decreased by 44.4, whereas beam-on time increased by 2.8 minutes when increasing fields to 19 from 9. Reoptimization with Ethos 1.1 Maintenance Release 1 resulted in decreased MU and minimal score changes. Conclusions: The scorecard is an effective tool to adjust an Ethos CDT to improve the average calculated plan quality. It also allowed for easy evaluation of the dosimetric impact of other planning parameters (beam arrangements and use of DVHe) to identify the best approach. Using a finely tuned CDT is expected to improve planning efficiency and decrease intrainstitutional plan quality variability, benefiting cone beam computed tomography-guided adaptive radiation therapy.

Identifiers

PMID39045406
PMCPMC11264169

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.