ArticleJPRAS open2024
The use of Fibrin Sealants in Reducing Drain Output in Abdominoplasty: Is it Useful?
Article in JPRAS open, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Fibrin Sealant and Abdominoplasty: An Ally Against Complications?Aesthetic plastic surgery · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Abdominoplasty is a common surgical procedure in which excess abdominal skin and fat are reduced to improve body contouring. Fibrin sealant has been proposed to reduce postsurgical bleeding and exudation. In this study, we evaluated whether there was a significant statistical difference in surgical output between the use of fibrin glue and its nonuse in abdominoplasty surgery, specifically in reducing bleeding and exudation. Material and methods: A retrospective chart review of 68 postbariatric abdominoplasty patients (58 females, 10 males) was performed. We divided the patients into Group A (30 cases, 44%), in which we used fibrin sealant, and Group B (38 cases, 56%), in which we did not use fibrin glue. We calculated the total amount of liquid in suction drainages until the day of their removal. Statistical analysis included the independent Results: The average drainage output in Group A was 620.0 ± 375.0 mL, whereas in Group B, it was 500.0 ± 290.0 mL. Results indicate an insignificant correlation between the use of fibrin glue and the amount of liquid in the surgical drains ( Conclusion: The use of fibrin sealant surely has a high value in all surgical branches to reduce postoperative complications, but in our study, we did not find any advantages in its use for reducing surgical drain output in abdominoplasty patients.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.