Thickness Variations of Thermoformed and 3D-Printed Clear Aligners.

Ružica Bandić, Katarina Vodanović, Ivna Vuković Kekez, Ivana Medvedec Mikić, Ivan Galić, Danijela Kalibović Govorko

Abstract read
In one paragraph

Article in Acta stomatologica Croatica, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Acta stomatologica Croatica · 2025
    Article
  12. Article
  13. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ružica BandićDepartment of Orthodontics, University of Split School of Medicine.ORCID https://orcid.org/0000-0003-0811-6983
Katarina VodanovićDepartment of Orthodontics, University of Split School of Medicine.ORCID https://orcid.org/0000-0001-6985-584
Ivna Vuković KekezDepartment of Orthodontics, University of Split School of Medicine.ORCID https://orcid.org/0000-0001-9616-420X
Ivana Medvedec MikićDepartment of Endodontics and Restorative Dental Medicine, University of Split School of Medicine.ORCID https://orcid.org/0000-0003-0202-3399
Ivan GalićDepartment of Oral Surgery, University of Split School of Medicine.ORCID https://orcid.org/0000-0003-0387-9535
Danijela Kalibović GovorkoDepartment of Orthodontics, University of Split School of Medicine.ORCID https://orcid.org/0000-0002-2598-9009

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To assess thickness variations of thermoformed and 3D-printed clear aligners. Materials and Methods: Six different thermoplastic materials with different initial thicknesses were used for aligner thermoforming using Biostar® device (Biostar®, SCHEU-DENTAL GmbH, Iserlohn, Germany). Also, two different dental resins were used to create the printed aligners in three digitally designed thicknesses using IZZI Direct printer (3Dtech, Zagreb, Croatia). The aligners were measured using an electronic micrometer (ELECTRONIC UNIVERSAL MICROMETER, Schut Geometrical Metrology, Groningen, The Netherlands, accuracy: 0.001 mm) on a total of 20 points per aligner. Statistical analysis was performed using the JASP program (JASP, University of Amsterdam, Amsterdam, The Netherlands). Results: The difference between the thermoformed and printed groups was statistically significant. Significant differences between different thermoformed materials and between 3D-printed materials were found. The thickness of thermoformed aligners deviated more in the upper jaw, whereas the thickness of printed aligners deviated more in the lower jaw. Both differences were statistically significant. The greatest average deviation from the initial thickness was found in Duran 0.75; Erkodur 0.6; Erkoloc-Pro 1.0; IZZI 0.5; NextDent 0.6 and NextDent A 0.6. NextDent group had the lowest deviations for all teeth of both jaws, except for upper and lower first molar where NextDent A group was more accurate. Conclusions: Thermoformed aligners showed decreased values, while printed ones showed mostly increased values compared to the original material thickness. The highest mean deviation belonged to IZZI group, and the NextDent group had the lowest mean deviation. The thickness of both aligners was thinner at the edges compared to the thickness at cusps and fissures.

Indexed as

MeSH Terms: Orthodontic Appliances RemovableOrthodontic AppliancesOrthodonticsPrintingRemovableSynthetic ResinsThree-dimensionalThree-Dimensional Printing

Identifiers

PMID39036327
PMCPMC11256873

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.