ArticleBMC oral health2024
Accuracy evaluation of dental CBCT and scanned model registration method based on pulp horn mapping surface: an in vitro proof-of-concept.
Article in BMC oral health, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Effect of Fiducial Marker Design (Shape, Size, and Configuration) on the Trueness and Precision of CBCT Marker-Geometry Reproduction for CBCT-Intraoral Scan Registration: An In Vitro Study.Diagnostics (Basel, Switzerland) · 2026Article
- Evaluation of CBCT reconstructed tooth models at different thresholds and voxels and their accuracy in fusion with IOS data: an in vitro validation study.BMC oral health · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
BACKGROUND AND
aim3D fusion model of cone-beam computed tomography (CBCT) and oral scanned data can be used for the accurate design of root canal access and guide plates in root canal therapy (RCT). However, the pose accuracy of the dental pulp and crown in data registration has not been investigated, which affects the precise implementation of clinical planning goals. We aimed to establish a novel registration method based on pulp horn mapping surface (PHMSR), to evaluate the accuracy of PHMSR versus traditional methods for crown-pulp registration of CBCT and oral scan data. MATERIALS AND
methodsThis vitro study collected 8 groups of oral scanned and CBCT data in which the left mandibular teeth were not missing, No. 35 and No. 36 teeth were selected as the target teeth. The CBCT and scanned model were processed to generate equivalent point clouds. For the PHMSR method, the similarity between the feature directions of the pulp horn and the surface normal vectors of the crown were used to determine the mapping points in the CBCT point cloud that have a great influence on the pulp pose. The small surface with adjustable parameters is reconstructed near the mapping point of the crown, and the new matching point pairs between the point and the mapping surface are searched. The sparse iterative closest point (ICP) algorithm is used to solve the new matching point pairs. Then, in the C + + programming environment with a point cloud library (PCL), the PHMSR, the traditional sparse ICP, ICP, and coherent point drift (CPD) algorithms are used to register the point clouds under two different initial deviations. The root square mean error (RSME) of the crown, crown-pulp orientation deviation (CPOD), and position deviation (CPPD) were calculated to evaluate the registration accuracy. The significance between the groups was tested by a two-tailed paired t-test (p < 0.05).
resultsThe crown RSME values of the sparse ICP method (0.257), the ICP method (0.217), and the CPD method (0.209) were not significantly different from the PHMSR method (0.250). The CPOD and CPPD values of the sparse ICP method (4.089 and 0.133), the ICP method (1.787 and 0.700), and the CPD method (1.665 and 0.718) than for the PHMSR method, which suggests that the accuracy of crown-pulp registration is higher with the PHMSR method.
conclusionCompared with the traditional method, the PHMSR method has a smaller crown-pulp registration accuracy and a clinically acceptable deviation range, these results support the use of PHMSR method instead of the traditional method for clinical planning of root canal therapy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.