Evidence map›Paper›PMID 39034333›Full record

ArticleNeurosurgical review2024

Pterional vs. lateral supraorbital approach in the management of middle cerebral artery aneurysms: insights from a phantom model study.

Amir Amini, Vanessa M Swiatek, Klaus-Peter Stein, Ali Rashidi, I Erol Sandalcioglu, Belal Neyazi

Abstract read
In one paragraph

Article in Neurosurgical review, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Amir AminiDepartment of Neurosurgery, University Hospital Magdeburg, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Saxony Anhalt, Germany.ORCID http://orcid.org/0000-0001-8360-9046
Vanessa M SwiatekDepartment of Neurosurgery, University Hospital Magdeburg, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Saxony Anhalt, Germany.ORCID http://orcid.org/0000-0001-7264-0013
Klaus-Peter SteinDepartment of Neurosurgery, University Hospital Magdeburg, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Saxony Anhalt, Germany.ORCID http://orcid.org/0000-0003-4461-7769
Ali RashidiDepartment of Neurosurgery, University Hospital Magdeburg, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Saxony Anhalt, Germany.ORCID http://orcid.org/0000-0003-2047-7175
I Erol SandalciogluDepartment of Neurosurgery, University Hospital Magdeburg, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Saxony Anhalt, Germany.ORCID http://orcid.org/0000-0002-8922-2616
Belal NeyaziDepartment of Neurosurgery, University Hospital Magdeburg, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Saxony Anhalt, Germany. belal.neyazi@med.ovgu.de.ORCID http://orcid.org/0000-0002-3163-0545

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The pterional approach has traditionally been employed for managing middle cerebral artery (MCA) aneurysms. With potential benefits like reduced surgical morbidity and improved postoperative recovery, the lateral supraorbital approach (LSO) should be considered individually based on aneurysm morphology, location and patient-specific variations of the MCA anatomy, which requires considerable technical expertise traditionally acquired through years of experience. The goal of this study was the development and evaluation of a novel phantom simulator in the context of clinical decision-making in the managmement of MCA aneurysms. For this purpose, high-fidelity simulators inclusive of MCA models with identical M1- and bifurcation aneurysms were manufactured employing 3D reconstruction techniques, additive manufacturing and rheological testings. Medical students, neurosurgical residents, and seasoned neurosurgeons (n = 22) tested and evaluated both approaches. Participants' performances and progress over time were assessed based on objective metrics. The simulator received positive ratings in face and content validity, with mean scores of 4.9 out of 5, respectively. Objective evaluation demonstrated the model's efficacy as a practical training tool, particularly among inexperienced participants. While requiring more technical expertise, results of the comparative analysis suggest that the LSO approach can improve clipping precision and outcome particularly in patients with shorter than average M1-segments. In conclusion, the employed methodology allowed a direct comparison of the pterional and LSO approaches, revealing comparable success rates via the LSO approach while reducing operation time and complication rate. Future research should aim to establish simulators in the context of clinical decision making.

Indexed as

Intracranial AneurysmMiddle Cerebral ArteryNeurosurgical ProceduresHumansNeurosurgeonsPhantoms, Imaging

Identifiers

PMID39034333
PMCPMC11271347

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.