Evidence map›Paper›PMID 39033113›Full record

ArticleBMC musculoskeletal disorders2024

Screw placement through a higher medial portal provides better initial stability in arthroscopic ACL tibial avulsion fracture fixation: a finite element analysis.

Yang Xiao, Changhao Shi, Geyang Deng, Zichu Ding, Jinhuang Xu, Bin Chen

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yang XiaoDivision of Orthopaedics and Traumatology, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, Guangzhou, China.
Changhao ShiDivision of Orthopaedics and Traumatology, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, Guangzhou, China.
Geyang DengDivision of Orthopaedics and Traumatology, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, Guangzhou, China.
Zichu DingDivision of Orthopaedics and Traumatology, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, Guangzhou, China.
Jinhuang XuDepartment of Trauma and Joint Surgery, The Fourth Hospital affiliated to the Guangzhou Medical University, Guangzhou, China.
Bin ChenDivision of Orthopaedics and Traumatology, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, Guangzhou, China. chenbin1@smu.edu.cn.ORCID https://orcid.org/0000-0002-6869-1843

Funding

National Natural Science Foundation of China 12272164Science and Technology Program of Guangzhou 202102080570
6 · The paper itself

Abstract

objectiveThe objective of this study was to investigate the initial stability of different screw placements in arthroscopic anterior cruciate ligament (ACL) tibial avulsion fracture fixation.

methodsA three-dimensional knee model at 90° flexion was utilized to simulate type III ACL tibial avulsion fracture and arthroscopic screw fixation through different portals, namely the central transpatellar tendon portal (CTP), anterolateral portal (ALP), anteromedial portal (AMP), lateral parapatellar portal (LPP), medial parapatellar portal (MPP), lateral suprapatellar portal (LSP), medial suprapatellar portal (MSP). A shear force of 450 N was applied to the finite element models at 30° flexion to simulate the failure condition. The displacement of the bony fragment and the volume of the bone above 25,000 µ-strain (damaged bone volume) were calculated around the screw path.

resultsWhen the screw was implanted through CTP, the displacement of the bony fragment reached the maximum displacement which was 1.10 mm and the maximum damaged bone volume around the screw path was 148.70 mm

conclusionScrews implanted through a higher medial portal generated less displacement of the bony fragment and a minimum detrimental strain around the screw path. The findings are clinically relevant as they provide biomechanical evidence on optimizing screw placement in arthroscopic ACL tibial avulsion fracture fixation.

Indexed as

ArthroscopyBone ScrewsFinite Element AnalysisFracture Fixation, InternalFractures, AvulsionTibial FracturesAnterior Cruciate LigamentAnterior Cruciate Ligament InjuriesBiomechanical PhenomenaHumansACL avulsion fractureArthroscopic screw fixationBiomechanical effectFinite element analysisPortal

Identifiers

PMID39033113
PMCPMC11264942

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.