Evaluation of the measurement accuracy and uncertainty of a solid-state detector under diagnostic x-ray beam conditions.

Sho Maruyama, Hiroki Saitou, Toru Negishi, Michiharu Sekimoto

Abstract readEvaluation Study
In one paragraph

Article in Journal of applied clinical medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Sho MaruyamaDepartment of Radiological Technology, Gunma Prefectural College of Health Sciences, Gunma, Japan.ORCID https://orcid.org/0000-0003-0140-5993
Hiroki SaitouDepartment of Medical Radiology, Faculty of Medical Technology, Teikyo University, Tokyo, Japan.
Toru NegishiDepartment of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, Tokyo, Japan.
Michiharu SekimotoFaculty of Medical Technology, Niigata University of Health and Welfare, Niigata, Japan.ORCID https://orcid.org/0000-0002-6258-2910

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveAn accurate measurement of x-ray beams is expected to reduce the uncertainties associated with estimating radiation risk to patients in clinical settings. To perform assessment tasks based on the readings of a solid-state detector (SSD) using semiconductor technology, the characteristics of the detector should be elucidated. In this study, we evaluated the measurement accuracy of a new SSD under diagnostic x-ray beam conditions in terms of air kerma, tube voltage, and half-value layer (HVL). The performance of the SSD was then compared with those of reference instruments.

methodsThe tube voltage was varied within the range of 50-120 kV in steps of 10 kV and the thickness and materials of additional filters were concurrently changed (several combinations were tested). In addition, the dose rate and energy dependence of the SSD were also investigated. These effects were analyzed based on statistical significance tests. Furthermore, the expanded uncertainties in the series of measurements were meticulously calculated.

resultsThe results showed average relative differences of -3.26 ± 1.33%, 0.44 ± 1.01%, and -2.60 ± 3.31% for air kerma, tube voltage, and HVL, respectively. Furthermore, air kerma did not exhibit any dependence on dose rate and energy, in contrast to tube voltage and HVL measurements.

conclusionThe measurement values of the SSD fall within the acceptable range of uncertainty, highlighting its measurement accuracy and reliability. Furthermore, based on the characteristics elucidated by this study, valuable insights are provided concerning the assurance of appropriate measurement values in clinical settings.

Indexed as

Radiation DosageHumansPhantoms, ImagingRadiometrySemiconductorsUncertaintyX-Raysair kermadiagnostic x‐rayhalf‐value layer (HVL)measurement accuracysolid‐state detector (SSD)tube voltageuncertainty

Identifiers

PMID39031856
PMCPMC11492300

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.