ArticleJournal of applied clinical medical physics2024
Technical Notes: Robustness of three-dimensional treatment and imaging isocenter testing using a new gel dosimeter and kilovoltage CBCT.
Article in Journal of applied clinical medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- An Integrated Approach to Verify Spot Position and Isocenter in Image-Guided Proton Therapy.International journal of particle therapy · 2025Article
- Spatial accuracy of dose delivery significantly impacts the planning target volume margin in linear accelerator-based intracranial stereotactic radiosurgery.Scientific reports · 2025Article
- Technical Notes: Robustness of three-dimensional treatment and imaging isocenter testing using a new gel dosimeter and kilovoltage CBCT.Journal of applied clinical medical physics · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
backgroundCoincidence of the treatment and imaging isocenter coordinates is required to safely perform small-margin treatments, such as stereotactic radiosurgery of multiple brain metastases. A comprehensive and direct methodology for verifying concordance of kilovoltage cone-beam computed tomography (kV-CBCT) and treatment coordinates using an x-ray CT-based polymer gel dosimeter (dGEL) and onboard kV-CBCT was previously reported. Using this methodology, we tested the ability of a new commercially available x-ray CT-based polymer dGEL with a rapid response to provide efficient quality assurance (QA). PURPOSE: The aim of this study was to evaluate the robustness of the three-dimensional geometric QA methodology using dGEL.
methodsThe dGEL were commercially manufactured. The prescribed dose for each field was determined by visually identifying the 5, 10, and 20 Gy isodose lines. A linear accelerator was used to irradiate the gels with seven non-coplanar beams. An in-house analysis program was used to identify the beam axes and treatment isocenter in kV-CBCT coordinates by processing the pre- and post-irradiation CBCT images. The impact of the radiation dose on the test reproducibility was examined, and the detectability of an intentional geometric error was assessed.
resultsThe treatment isocenter was within 0.4 mm of the imaging isocenter for all radiation doses. The residual error of the test with the intentional error was within 0.2 mm. The analysis and image quality variations for a single dGEL introduced displacement errors less than 0.3 mm.
conclusionsThe test assessed the coincidence of treatment and kV-CBCT isocenter coordinates and detected errors with high robustness. Even for a 10 Gy dose, the test yielded results comparable with those obtained using higher radiation doses owing to the rapid response of the dGEL dosimeter.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.