Evidence map›Paper›PMID 39031633›Full record

ArticleJournal of applied clinical medical physics2024

Technical Notes: Robustness of three-dimensional treatment and imaging isocenter testing using a new gel dosimeter and kilovoltage CBCT.

Riki Oshika, Hidenobu Tachibana, Kazuya Seki, Rie Tachibana, Shunsuke Moriya, Takeji Sakae

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Riki OshikaDegree Programs in Comprehensive Human Sciences, Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki, Japan.
Hidenobu TachibanaRadiation Safety and Quality Assurance division, National Cancer Center Hospital East, Chiba, Japan.
Kazuya SekiRadiation Safety and Quality Assurance division, National Cancer Center Hospital East, Chiba, Japan.
Rie TachibanaTriangle Products Co. Ltd., Chiba, Japan.
Shunsuke MoriyaFaculty of Medicine, University of Tsukuba, Ibaraki, Japan.
Takeji SakaeFaculty of Medicine, University of Tsukuba, Ibaraki, Japan.

Funding

Triangle Products Co., Ltd. C2019-134
6 · The paper itself

Abstract

backgroundCoincidence of the treatment and imaging isocenter coordinates is required to safely perform small-margin treatments, such as stereotactic radiosurgery of multiple brain metastases. A comprehensive and direct methodology for verifying concordance of kilovoltage cone-beam computed tomography (kV-CBCT) and treatment coordinates using an x-ray CT-based polymer gel dosimeter (dGEL) and onboard kV-CBCT was previously reported. Using this methodology, we tested the ability of a new commercially available x-ray CT-based polymer dGEL with a rapid response to provide efficient quality assurance (QA). PURPOSE: The aim of this study was to evaluate the robustness of the three-dimensional geometric QA methodology using dGEL.

methodsThe dGEL were commercially manufactured. The prescribed dose for each field was determined by visually identifying the 5, 10, and 20 Gy isodose lines. A linear accelerator was used to irradiate the gels with seven non-coplanar beams. An in-house analysis program was used to identify the beam axes and treatment isocenter in kV-CBCT coordinates by processing the pre- and post-irradiation CBCT images. The impact of the radiation dose on the test reproducibility was examined, and the detectability of an intentional geometric error was assessed.

resultsThe treatment isocenter was within 0.4 mm of the imaging isocenter for all radiation doses. The residual error of the test with the intentional error was within 0.2 mm. The analysis and image quality variations for a single dGEL introduced displacement errors less than 0.3 mm.

conclusionsThe test assessed the coincidence of treatment and kV-CBCT isocenter coordinates and detected errors with high robustness. Even for a 10 Gy dose, the test yielded results comparable with those obtained using higher radiation doses owing to the rapid response of the dGEL dosimeter.

Indexed as

Cone-Beam Computed TomographyRadiosurgeryRadiotherapy DosageRadiotherapy Planning, Computer-AssistedBrain NeoplasmsGelsHumansImage Processing, Computer-AssistedImaging, Three-DimensionalParticle AcceleratorsPhantoms, ImagingQuality Assurance, Health CareRadiation DosimetersRadiometryRadiotherapy, Intensity-ModulatedGels3D starshotdGEL™gel dosimetryrobustnessX‐ray CT‐based gel dosimeter

Identifiers

PMID39031633
PMCPMC11492395

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.