Evidence map›Paper›PMID 39027831›Full record

ArticleJournal of family medicine and primary care2024

Comparison of indirect cyanmethaemoglobin method and TrueHb haemometer point of care test with direct cyanmethaemoglobin (gold standard) method for strengthening anaemia detection at primary health care level.

Rupinder Khurana, Arun Kumar Aggarwal, M Thungapathra, Vivek Sagar

Abstract read
In one paragraph

Article in Journal of family medicine and primary care, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Rupinder KhuranaDepartment of Community Medicine and School of Public Health, Postgraduate Institute of Medical Education and Research Chandigarh, India.
Arun Kumar AggarwalDepartment of Community Medicine and School of Public Health, Postgraduate Institute of Medical Education and Research Chandigarh, India.
M ThungapathraDepartment of Biochemistry, Postgraduate Institute of Medical Education and Research Chandigarh, India.
Vivek SagarDepartment of Community Medicine and School of Public Health, Postgraduate Institute of Medical Education and Research Chandigarh, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: The most reliable indicator for anaemia diagnosis at the population level is haemoglobin (Hb) estimation. The direct cyanmethaemoglobin method is considered the gold standard method for haemoglobin estimation. However, for resource constraint areas like primary health care (PHC) level, either blood samples are transported on filter paper for Hb testing (indirect cyanmethaemoglobin method) in laboratory or point of care testing is commonly used. Therefore, a comparative analysis of haemoglobin estimation of direct with indirect cyanmethaemoglobin method and also with TrueHb (Wrig Nanosystems Pvt. Ltd.) haemometer was done to strengthen anaemia diagnosis at the PHC level. Materials and Methods: This was a cross-sectional study. A total of 90 participants above 9 years of age, who visited the outpatient department (OPD) of health centre, Kheri and gave consent were included. Comparative analysis was done between Hb concentration assessed by indirect cyanmethaemoglobin method and TrueHb haemometer device against the gold standard method. Results: The mean Hb value estimated by direct method, TrueHb haemometer and indirect methods (filter paper A, B and C) was 11.42 ± 1.59 g/dl, 11.52 ± 1.54 g/dl, 10.66 ± 1.52 g/dl, 9.84 ± 1.50 g/dl and 10.19 ± 1.62 g/dl, respectively. There was no significant difference found between the mean Hb concentration estimated by the direct method and the TrueHb haemometer device. However, there was a significant difference in mean Hb values between the direct method and the indirect method. Therefore, regression analysis was done to estimate the correction factor for the indirect method. Conclusion: TrueHb metre device gave promising results in comparison to the gold standard method and can be used if resource permits in PHC centres. Indirect methods of haemoglobin estimation can be an alternative in resource-constraint settings, specifically for surveys. However, further studies are required for the validation of the indirect method.

Indexed as

Anaemiacyanmethaemoglobin methodhaemoglobin estimationpoint of care testTruehb haemometer device

Identifiers

PMID39027831
PMCPMC11254055

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.