Evidence map›Paper›PMID 39026270›Full record

ArticleBMC medical informatics and decision making2024

Hybridized deep learning goniometry for improved precision in Ehlers-Danlos Syndrome (EDS) evaluation.

Thirumalesu Kudithi, J Balajee, R Sivakami, T R Mahesh, E Mohan, Suresh Guluwadi

Abstract read
In one paragraph

Article in BMC medical informatics and decision making, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Accuracy of the Automated Range of Motion Observer and Reporter Software for Fully Automated Joint Measurement From Patient Videos.Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Thirumalesu KudithiSchool of Technology, The Apollo University, Chittoor, India.
J BalajeeDepartment of Computer Science and Engineering, Mother Theresa Institute of Engineering and Technology, Palamaner, Chittoor, Andhra Pradesh, 517408, India.
R SivakamiDepartment of Computer Science and Engineering, Sona College of Technology, Salem, 636005, India.
T R MaheshDepartment of Computer Science and Engineering, JAIN (Deemed-to-Be University), Bengaluru, 562112, India.
E MohanDepartment of ECE, Saveetha School of Engineering, SIMATS, Chennai, Tamilnadu, India.
Suresh GuluwadiAdama Science and Technology University, Adama, 302120, Ethiopia. suresh.guluwadi@astu.edu.et.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundGeneralized Joint Hyper-mobility (GJH) can aid in the diagnosis of Ehlers-Danlos Syndrome (EDS), a complex genetic connective tissue disorder with clinical features that can mimic other disease processes. Our study focuses on developing a unique image-based goniometry system, the HybridPoseNet, which utilizes a hybrid deep learning model.

objectiveThe proposed model is designed to provide the most accurate joint angle measurements in EDS appraisals. Using a hybrid of CNNs and HyperLSTMs in the pose estimation module of HybridPoseNet offers superior generalization and time consistency properties, setting it apart from existing complex libraries. METHODOLOGY: HybridPoseNet integrates the spatial pattern recognition prowess of MobileNet-V2 with the sequential data processing capability of HyperLSTM units. The system captures the dynamic nature of joint motion by creating a model that learns from individual frames and the sequence of movements. The CNN module of HybridPoseNet was trained on a large and diverse data set before the fine-tuning of video data involving 50 individuals visiting the EDS clinic, focusing on joints that can hyperextend. HyperLSTMs have been incorporated in video frames to avoid any time breakage in joint angle estimation in consecutive frames. The model performance was evaluated using Spearman's coefficient correlation versus manual goniometry measurements, as well as by the human labeling of joint position, the second validation step. OUTCOME: Preliminary findings demonstrate HybridPoseNet achieving a remarkable correlation with manual Goniometric measurements: thumb (rho = 0.847), elbows (rho = 0.822), knees (rho = 0.839), and fifth fingers (rho = 0.896), indicating that the newest model is considerably better. The model manifested a consistent performance in all joint assessments, hence not requiring selecting a variety of pose-measuring libraries for every joint. The presentation of HybridPoseNet contributes to achieving a combined and normalized approach to reviewing the mobility of joints, which has an overall enhancement of approximately 20% in accuracy compared to the regular pose estimation libraries. This innovation is very valuable to the field of medical diagnostics of connective tissue diseases and a vast improvement to its understanding.

Indexed as

Deep LearningEhlers-Danlos SyndromeArthrometry, ArticularHumansCorrelationDiagnosticsElbowFifth fingerJointsKneesLSTMManualMeasurementPose estimationSpatialTemporalThumb

Identifiers

PMID39026270
PMCPMC11264507

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.