ArticleAJNR. American journal of neuroradiology2024
Initial Experience with the Derivo 2Heal Flow Diverter under Standard or Reduced-Dose Single Antiplatelet Therapy.
Article in AJNR. American journal of neuroradiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Single antiplatelet therapy and tirofiban bridged with surface modified flow diverters for ruptured blood blister-like aneurysms: single center experience and systematic review.Journal of neurointerventional surgery · 2026Pooled it
- Comparative hemocompatibility assessment of fibrin/heparin-coated and PMEA-coated flow diverters.Journal of materials science. Materials in medicine · 2026Article
- Efficacy and safety of Derivo embolization device in intracranial aneurysms: A systematic review and Meta-Analysis.Neuroradiology · 2025Review
- Impact of surface coating on postinterventional DWI lesions: A comparative analysis of coated and uncoated FRED and DERIVO flow-diverters in the treatment of intracranial aneurysms.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025Article
- Pilot feasibility study of intraprocedural transcranial Doppler monitoring to assess Heal coating thrombogenicity in flow diversion.Frontiers in neurologyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
background and purposeFlow diverters with surface modifications or coatings have been recently introduced to clinical practice with the expectation that they can reduce the rate of thromboembolic complications and residual aneurysms. The purpose of this study is to evaluate the utility of the Derivo 2Heal (D2H) device, a new fibrin and heparin-coated flow diverter. MATERIALS AND
methodsPatients treated by a single operator by using the D2H were retrospectively evaluated for demographic data, aneurysm characteristics, procedural variables, and follow-up data. All patients were treated by using a single D2H, monitored by platelet function testing and kept under single antiplatelet therapy with regular or half-dose clopidogrel or prasugrel after the procedure.
resultsTwenty patients with 26 aneurysms were treated. Three presented acutely with subarachnoid hemorrhage. Adjunctive devices were used in 6 patients. There were no technical failures and 2 periprocedural self-limited nonthrombotic minor adverse events. During follow-up, 1 of the acutely ruptured aneurysms reruptured, and 1 patient had a visual TIA. All patients were doing well clinically (19 with mRS of 0 and 1 with 1) at the last follow-up after discharge. The rates of total occlusion on very early angiographic (MRA/CTA or DSA, mean: 2.4 months), DSA (mean: 5.8 months), and midterm angiographic (mean: 14.5 months) follow-up for all versus uncoiled aneurysms were 68% versus 70%, 77.8% versus 90.0%, and 91.7% versus 90.1%, respectively.
conclusionsThe absence of permanent neurologic deficits in the periprocedural period and favorable occlusion rates in this preliminary study suggest that the novel coating comprising fibrin and heparin may have the potential to increase the safety and efficacy of flow diversion and needs to be further studied by comparing the D2H device with its bare counterpart and other coated or surface-modified flow diverters.